Accident Report Detail

Accident Summary Nr: 1004456 - Employee killed when crushed between culvert and dozer

Accident Summary Nr: 1004456 -- Report ID: 0253620 -- Event Date: 10/09/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11593051310/10/199116110Dpw Highway Department Broome County

Abstract: At approximately 8:30 a.m. on October 9, 1991, Employee #1 was clearing a creek bed of silt and other debris with a 1982 John Deere 350C dozer. The dozer entered a culvert and Employee #1 was crushed between the top of the culvert and the fuel tank on the dozer. The ROPS structure had been removed from the machine. No one witnessed the accident.

Keywords: CLEARANCE, WORK RULES, EQUIPMENT OPERATOR, ROPS, CONSTRUCTION, CAUGHT BETWEEN, CRUSHED, BULLDOZER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115930513 Fatality Other Grader, dozer and scraper operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.