Accident Summary Nr: 100403.015 - Employee sustains multiple injuries when struck by tree

Accident Summary Nr: 100403.015 -- Report ID: 0155010 -- Event Date: 10/30/2017
Inspection NrDate OpenedSICNAICSEstablishment Name
1274648.01511/01/2017921140Fairfax, Town Of

Abstract: At 2:00 p.m. on October 30, 2017, Employee #1, a municipality highway foreman, and his two-man crew, were conducting after storm clean-up operations in the aftermath of a wind storm that knocked trees across roadways and caused significant damage to the above ground utility lines. During the clean-up operations, Employee #1 attempted to cut a white pine tree that had fallen across the roadway using a Stihl MS 311 chainsaw, Serial number 299009719, equipped with a 20 inch rollomatic bar. The pine tree was approximately 45 inches in diameter on the stump and formed two codominant stems at 8 feet in height. The stem on the northern side separated from the stump and fell onto the utility line during the period of high southeastern winds. The broken section was 20 inches on the butt-end and was estimated to be 50 feet in length. All three of the power lines in the area of the fallen tree where laying on the ground and the telecommunication line was pinned to the ground under the weight of the tree. When Employee #1 made a cut, the top portion of the tree sprung back, due to the relief of the tension on the stretched telecommunication line, and struck the employee. The employee was wearing a hard hat and safety glasses. As a result of being struck by the tree, Employee #1 sustained multiple skull fractures, a brain bleed, head lacerations, a fractured spinal cord, a fractured sternum, a collapsed lung, and paralysis of his lower extremities. The employee was evaluated by first responders and transported to a nearby medical center by ambulance for treatment.

Keywords: Brain, Chain Saw, Collapse, Emergency Response, Falling Object, Fracture, Hard Hat, Hemorrhage, Laceration, Lung, PPE, Paralysis, Power Lines, Skull, Struck By, Tree Trimming, Vertebra

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1274648.015 61 M Hospitalized injury Highway Maintenance Worker

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close