Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 1001312 - Employee amputates fingertip in unguarded riveter opening

Accident Summary Nr: 1001312 -- Report ID: 0751910 -- Event Date: 12/01/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10194041912/01/198636330Webster City Products Company

Abstract: Employee #1 was cleaning oil from the shaft of a Delta 10K riveter (Model No. DD 17-Striel #8809) when the machine cycled. She had been standing in front of the machine and had reached around the back side, but she did not remember if she stepped on the foot trip. Employee #1's fingertip was amputated in a 0.625-in.-wide by 1.75-in.-long opening. (A plastic guard covering the opening was installed approximately 5 working days after the accident.)

Keywords: AMPUTATED, RIVET PRESS, FINGER, WORK RULES, CLEANING, FOOT CONTROL, LOCKOUT, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101940419 Non Hospitalized injury Amputation Misc. metal,plastic,stone&glass-working mach. op's

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.