Inspection: 1573298.015 - Mitac Information Systems Corp

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 1573298.015
Report ID: 0950614
Date Opened: 01/19/2022

Site Address:
Mitac Information Systems Corp
39889 Eureka Drive
Newark, CA 94560

Mailing Address:
39889 Eureka Drive, Newark, CA 94560

Union Status: NonUnion

SIC:

NAICS: 519190/All Other Information Services


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/04/2022

Emphasis:

Case Closed: 06/08/2022


Related Activity
Type Activity Nr Safety Health
Accident 1846143
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $1,685 $0 $1,685
Current Penalty $0 $0 $0 $1,685 $0 $1,685
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203(A)(7) 05/05/2022 $750 $750 $0 Z - Issued  
2. 01002 Other 3276(F) 05/05/2022 06/09/2022 $935 $935 $0 Z - Issued  

Investigation Summary

Investigation Nr: 142869.015
Event: 12/20/2021
Employee slips and strikes metal rail resulting in serious i

Mitac Information Systems Corp. is an employer engaged in computer hardware manufacturing. Prior to the accident, an employee, a maintenance lead, and a coworker, another maintenance employee, were assigned to run network and sensor cables in the drop ceiling area above the test chamber room. At 2:20 p.m. on December 20, 2021, the employee was in the drop ceiling area and lost balance, striking his chest against a metal rail in the drop ceiling. The employee was transported to a hospital in Fremont, CA. The employee was then transferred to another hospital in Castro Valley, CA that same night due to bleeding in the liver. The employee was admitted for trauma care, including fractures of the right 4th through 9th ribs, a small right-sided pneumothorax, and a liver mass that was diagnosed as a traumatic hematoma. The employee was discharged on December 23, 2021. The main factor that caused the accident was that the employee went against instruction from the supervisor to complete the task using a ladder from the ground floor. This was determined the previous day because of the insufficient work space in the drop ceiling. The Division found no serious accident-related violations. The employer was cited for two general violations. Title 8 CCR 3203(a)(7): The employer did not provide safety training to maintenance employees. Title 8 CCR 3276(f): The employer did not provide ladder training to employees. Struck against metal beam

Keywords: Fall, Fracture, Ladder, Liver, Rib, Slip, Struck Against, Subdural Hematoma, Tripped, Work Rules

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1573298.015 64 M Hospitalized injury Misc. electrical & electronic equipment repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.