Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1454363.015 - Toledo Molding & Die Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1454363.015
Report ID: 0524700
Date Opened: 01/08/2020

Site Address:
Toledo Molding & Die Inc.
1441 N. Maule Rd.
Tiffin, OH 44883

Mailing Address:
1441 N. Maule Rd., Tiffin, OH 44883

Union Status: Union

SIC:

NAICS: 326199/All Other Plastics Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/08/2020

Emphasis: N:Amputate

Case Closed: 04/29/2020


Related Activity
Type Activity Nr Safety Health
Referral 1531182 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $7,711 $0 $0 $0 $0 $7,711
Current Penalty $3,856 $0 $0 $0 $0 $3,856
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 E 02/24/2020 $3,856 $7,711 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 123013.015
Event: 01/02/2020
Employee suffers partial amputation of finger when stud beco

At 4:30 a.m. on January 2, 2020, an employee was working for a firm that manufactured products made of plastic. She worked as a machine operator. She was a support operator. Support operators were assigned to multiple machines and presses daily. Support operators relieved regularly assigned operators for breaks and for lunch. In this incident, she was operating a TSM 12 model number MSE1918 Tiffin screw machine. The machine ran at 500 rpm. The employee was wearing Body Guard gloves from which material had been removed from the portions that covered the thumb and index finger. Several employees interviewed later stated that some employees cut the fingers out of their gloves to perform specific tasks such as but not limited to installing gaskets on parts. In this incident, the employee was holding a metal threaded stud in a powered nut driver. She was going to install the metal threaded stud into a plastic housing. She was holding the stud with her thumb and index finger when the stud became entangled in the employee's glove. Her hand to thrust into the plastic lamp housing, with the force concentrated on her right ring finger. The employee suffered a laceration and a dislocation of the finger. The dislocation of the right ring finger required surgery that resulted in a surgical amputation below the first knuckle or joint. The employee was treated without hospitalization. The employer did not ensure that employees' protective gloves were not damaged and removed from service while employees were operating the Tiffin screw machine. Employees operating the screw machine while wearing gloves with the thumb and index finger cut out were exposed to a "caught-in" hazard.

Keywords: Amputated, Amputation, Caught In, Dislocated, Finger, Glove, Inadequate Maint, Laceration, Machine operator, PPE, Partial Amputation, Rotating Parts, Struck Against, Surgical Amputation, Thumb, Training

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1454363.015 30 F Non Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.