Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1426075.015 - 317723616 - Ever Fresh Fruit Company

Inspection Information - Office: Or-E-Portland - Safety 1 1054111

 

Inspection Nr: 1426075.015
Report ID: 1054111
Date Opened: 03/15/2019

Site Address:
317723616 - Ever Fresh Fruit Company
35855 Se Kelso Rd
Boring, OR 97009

Mailing Address:
Po Box 1177, Sandy, OR 97055

Union Status: NonUnion

SIC:2037

NAICS: 311411/ Frozen Fruit, Juice, and Vegetable Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/15/2019

Emphasis:

Case Closed: 01/06/2020


Related Activity
Type Activity Nr Safety Health
Inspection 1426784 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 1 4
Current Violations 2 1 1 4
Initial Penalty $3,600 $0 $2,800 $250 $0 $6,650
Current Penalty $3,600 $0 $2,800 $250 $0 $6,650
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C06 I 08/29/2019 09/10/2019 $1,600 $1,600 $0 Z - Issued  
2. 01002 Serious 19100147 C07 III A 08/29/2019 09/10/2019 $2,000 $2,000 $0 Z - Issued  
3. 02003 Repeat 19100147 C04 II 08/29/2019 09/10/2019 $2,800 $2,800 $0 Z - Issued  
4. 03004 Other OAR 437-001-0704(4) 08/29/2019 09/10/2019 $250 $250 $0 Z - Issued  

Investigation Summary

Investigation Nr: 119285.015
Event: 03/12/2019
Employee suffers steam burns from heat exchanger

At 6:42 p.m. on March 12, 2019, an employee was instructed by his manager to replace a temperature valve on a hot water heat exchanger. The steam and water supply were isolated however there were two points where the water pressure could be relieved and only one of those points had been opened and bled. The employee opened the line that had not been bled and steam hit the left side of his body burning his face, neck, abdomen, arm, and torso. The employee was hospitalized.

Keywords: Abdomen, Arm, Burn, Face, Heat Exchanger, Neck, Pressure Release, Steam, Steam Line, Torso, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1426075.015 59 M Hospitalized injury Industrial machinery repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close