Inspection Detail
Inspection: 1384740.015 - Pactiv Llc
Inspection Information - Office: Long Beach District Office
Site Address:
Pactiv Llc
12500 E Slauson Ave
Santa Fe Springs, CA 90670
Mailing Address:
12500 E Slauson Ave, Santa Fe Springs, CA 90670
Union Status: NonUnion
SIC:
NAICS: 326112/Plastics Packaging Film and Sheet (including Laminated) Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/14/2019
Emphasis:
Case Closed: 10/02/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1429737 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $800 | $0 | $800 |
| Current Penalty | $0 | $0 | $0 | $800 | $0 | $800 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3328(G) | 08/19/2019 | $800 | $800 | $0 | Z - Issued |
Investigation Summary
At 10:00 a.m. on February 21, 2019, an employee was working with a Parkinson Technologies, Inc. extruder machine (Model Number 004032-01). When the roll reached the correct size, he began to remove the roll to replace it. The employee placed his hands on the collar when it cracked and his left hand was pulled into the crack. The employee amputated his hand. He went to a clinic and then to Western Hand Clinic for treatment, but hospitalization was not required.
Keywords: Amputated, Amputation, Caught By, Hand
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1384740.015 | 55 | M | Non Hospitalized injury | Machine operators, not specified |
Translate