Inspection Detail
Inspection: 1381073.015 - Schaefer'S Electrical Enclosures, Inc.
Inspection Information - Office: Saint Louis Area Office
Site Address:
Schaefer'S Electrical Enclosures, Inc.
4680-A Nash Rd.
Scott City, MO 63780
Mailing Address:
4680-A Nash Rd., Scott City, MO 63780
Union Status: NonUnion
SIC:
NAICS: 332322/Sheet Metal Work Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/26/2019
Emphasis: P:Amputate, N:Amputate, L:Repvehicle
Case Closed: 02/26/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1429025 | Yes |
Investigation Summary
At approximately 3:00 a.m. on February 22, 2019, an employee was bending a piece of metal on a press brake. The employee attempted to rebend the piece to obtain a different angle. The employee placed the piece of metal in the brake improperly resulting in the part pinching his thumb tip as the machine cycled. The employee amputated the tip of the thumb. Even though not indicated, the employee most likely was hospitalized.
Keywords: Amputated, Amputation, Brake, Fingertip, Press Brake, Thumb
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1381073.015 | 30 | M | Non Hospitalized injury | Machine operators, not specified |