Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1351848.015 - Carbon Activated Corp

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 1351848.015
Report ID: 0950635
Date Opened: 10/05/2018

Site Address:
Carbon Activated Corp
250 E Manville St
Compton, CA 90220

Mailing Address:
250 E Manville St, Compton, CA 90220

Union Status: NonUnion

SIC:

NAICS: 325998/All Other Miscellaneous Chemical Product and Preparation Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/03/2019

Emphasis:

Case Closed: 09/08/2020


Related Activity
Type Activity Nr Safety Health
Accident 1389145
Complaint 1394013 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 2 5
Current Violations 3 2 5
Initial Penalty $37,685 $0 $0 $1,310 $0 $38,995
Current Penalty $16,200 $0 $0 $300 $0 $16,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5162(C) 04/03/2019 04/22/2019 $150 $560 $0 05/09/2019 O - Administrative Law Judge Order  
2. 01002 Other 5162(D) 04/03/2019 04/22/2019 $150 $750 $0 05/09/2019 O - Administrative Law Judge Order  
3. 02001 Serious 3203(A)(4) 04/03/2019 $5,400 $6,750 $0 05/09/2019 O - Administrative Law Judge Order  
4. 03001 Serious 3328(C) 04/03/2019 $5,400 $8,435 $0 05/09/2019 O - Administrative Law Judge Order  
5. 04001 Serious 3328(G) 04/03/2019 04/15/2019 $5,400 $22,500 $0 05/09/2019 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 114269.015
Event: 10/05/2018
Three employees suffer burns from oven fire

At approximately 10:30 a.m. on October 5, 2018, Employee #1, Employee #2, and Employee #3 removed the drying carbon from the drying oven located in the south corner of the plant. As Employee #1 opened the door of the oven, the carbon on the floor of the oven flashed in the direction of the opened door striking Employee #1, Employee #2, and Employee #3. Employee #1, Employee #2, and Employee #3 were taken to the company's clinic for burns suffered to their faces, arms, and hands. At the company's clinic, the clinic could not treat the burns, so the clinic notified the Compton Fire Department. The Compton Fire Department responded and transferred all three employees to Harbor UCLA for treatment. At Harbor UCLA, the three employees were treated at the emergency room for second degree burns to the face, arms, back of hands and then transferred to the USC Burn Center. Further investigation revealed the failure of the oven being air tight due to the condition of the oven door seals led to additional oxygen being introduced to the drying carbon that caused the carbon within the oven to smolder, not dry. Also, the failure of the oven's temperature alarm to operate properly during the drying of the activated carbon led to this accident because the oven's temperature alarm was turned off.

Keywords: Arm, Burn, Face, Hand, Oven

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1351848.015 34 M Hospitalized injury Management related occupations, n.e.c.
2 1351848.015 49 M Hospitalized injury Laborers, except construction
3 1351848.015 69 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close