Inspection Detail
Inspection: 1259338.015 - National Distribution Centers Llc
Inspection Information - Office: Monrovia District Office
Site Address:
National Distribution Centers Llc
4450 Edison Avenue
Chino, CA 91710
Mailing Address:
6725 Kimball Ave., Chino, CA 91708
Union Status: NonUnion
SIC:
NAICS: 484121/ General Freight Trucking, Long-Distance, Truckload
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/08/2018
Emphasis:
Case Closed: 04/30/2018
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1255144 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $0 | $0 | $0 | $1,125 | $0 | $1,125 |
| Current Penalty | $0 | $0 | $0 | $1,125 | $0 | $1,125 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 3324(A) | 02/08/2018 | $1,125 | $1,125 | $0 | Z - Issued |
Investigation Summary
At 6:30 p.m. on August 13, 2017, an employee was pushing a 90 inch by 161 inch horizontal gate closed when he heard a popping sound. The employee sustained an injury to his back and was hospitalized.
Keywords: Back
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1259338.015 | 27 | M | Hospitalized injury | Truck drivers, heavy |
Translate