Inspection Detail
Inspection: 1251859.015 - Geo Analytical Laboratories
Inspection Information - Office: Modesto District Office
Site Address:
Geo Analytical Laboratories
2300 Maryanne Drive
Turlock, CA 95382
Mailing Address:
2300 Maryanne Drive, Turlock, CA 95382
Union Status: NonUnion
SIC:
NAICS: 541380/Testing Laboratories
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/30/2017
Emphasis:
Case Closed: 10/09/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 1244803 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $0 | $0 | $0 | $260 | $0 | $260 |
| Current Penalty | $0 | $0 | $0 | $260 | $0 | $260 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 5162(E) | 08/30/2017 | 10/17/2017 | $130 | $130 | $0 | Z - Issued | ||
| 2. | 01002 | Other | 6151(E)(2) | 08/30/2017 | 10/17/2017 | $130 | $130 | $0 | Z - Issued |
Inspection: 1251859 - General Motors Corp Delco Products Div
Inspection Information - Office: Cincinnati Area Office
Site Address:
General Motors Corp Delco Products Div
2000 Forrer Blvd
Kettering, OH 45429
Mailing Address:
, , 00000
Union Status: Union
SIC:3694
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/15/1984
Emphasis:
Case Closed: 08/15/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360566939 |
Investigation Summary
SEVERAL EMPLOYEES FOR A GENERAL CONSTRUCTION CONTRACTOR WERE CUTTING, CHIPPING, AND REMOVING SECTIONS OF AN EXISTING CONCRETE FLOOR IN A PLANT SO THAT A NEW VIBRATION PAD COULD BE INSTALLED. ONE EMPLOYEE WAS USING A PORTABLE 120-VOLT BATTERY CHARGER TO ASSIST IN STARTING A SCOOT-CRETE POWER BUGGY BEING USED FOR THE REMOVAL OF THE MATERIALS. AFTER BEING USED TO START THE POWER BUGGY, THE BATTERY CHARGER (FOX PRODUCTS COMPANY, MODEL #572N-2) WAS POSITIONED NEXT TO A METAL RAILING. THE EMPLOYEE WAS SECURING THE EQUIPMENT WHEN THE CHARGER DEVELOPED A GROUND FAULT TO ITS CASE. THE BATTERY CHARGER WAS MISSING THE GROUNDING PRONG FROM ITS ATTACHMENT PLUG, AND NO GROUND-FAULT CIRCUIT INTERRUPTER WAS IN USE. WHEN THE EMPLOYEE MADE CONTACT WITH THE CHARGER AND THE METAL RAILING AT THE SAME TIME, HE WAS ELECTROCUTED.
Keywords: ELECTRICAL, EQUIPMENT GROUNDING, ELECTROCUTED, GROUND FAULT, E GI V, BATTERY CHARGER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1251859 | Fatality | Electric Shock | Occupation not reported |
Back to Top