Inspection Detail
Inspection: 1251842.015 - Kbs, Inc
Inspection Information - Office: Va-E-Richmond (Regional Office) - Safety 0355111
Site Address:
Kbs, Inc
1903 E. Marshall Street
Richmond, VA 23228
Mailing Address:
8050 Kimway Drive, Richmond, VA 23228
Union Status: NonUnion
SIC:
NAICS: 236220/Commercial and Institutional Building Construction
Inspection Type: Prog Related
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/16/2017
Emphasis: P:Fall, S:Fall
Case Closed: 10/26/2017
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Inspection | 1251452 | Yes | |
| Inspection | 1251572 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $3,430 | $0 | $0 | $845 | $0 | $4,275 |
| Current Penalty | $2,138 | $0 | $0 | $0 | $0 | $2,138 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260502 B01 | 08/21/2017 | $2,138 | $3,430 | $0 | 08/24/2017 | L - State Settlement | ||
| 2. | 02001 | Other | 16VAC25-160-10.C.3 | 08/21/2017 | $0 | $845 | $0 | 08/24/2017 | L - State Settlement | Citation has been deleted. |
Inspection: 1251842 - Freedom Electrical Contractors Inc
Inspection Information - Office: Cincinnati Area Office
Site Address:
Freedom Electrical Contractors Inc
2000 Forrer Blvd
Kettering, OH 45429
Mailing Address:
712 S Main St, Dayton, OH 45402
Union Status: Union
SIC:1731
NAICS: 0
Inspection Type: Unprog Rel
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/08/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/27/1986
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360566939 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $600 | $0 | $0 | $0 | $0 | $600 |
| Current Penalty | $200 | $0 | $0 | $0 | $0 | $200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260400 H01 | 08/23/1984 | 08/26/1984 | $100 | $300 | $0 | I - Informal Settlement | ||
| 2. | 01002 | Serious | 19260451 A04 | 08/23/1984 | 08/26/1984 | $100 | $300 | $0 | I - Informal Settlement |
Investigation Summary
SEVERAL EMPLOYEES FOR A GENERAL CONSTRUCTION CONTRACTOR WERE CUTTING, CHIPPING, AND REMOVING SECTIONS OF AN EXISTING CONCRETE FLOOR IN A PLANT SO THAT A NEW VIBRATION PAD COULD BE INSTALLED. ONE EMPLOYEE WAS USING A PORTABLE 120-VOLT BATTERY CHARGER TO ASSIST IN STARTING A SCOOT-CRETE POWER BUGGY BEING USED FOR THE REMOVAL OF THE MATERIALS. AFTER BEING USED TO START THE POWER BUGGY, THE BATTERY CHARGER (FOX PRODUCTS COMPANY, MODEL #572N-2) WAS POSITIONED NEXT TO A METAL RAILING. THE EMPLOYEE WAS SECURING THE EQUIPMENT WHEN THE CHARGER DEVELOPED A GROUND FAULT TO ITS CASE. THE BATTERY CHARGER WAS MISSING THE GROUNDING PRONG FROM ITS ATTACHMENT PLUG, AND NO GROUND-FAULT CIRCUIT INTERRUPTER WAS IN USE. WHEN THE EMPLOYEE MADE CONTACT WITH THE CHARGER AND THE METAL RAILING AT THE SAME TIME, HE WAS ELECTROCUTED.
Keywords: ELECTRICAL, EQUIPMENT GROUNDING, ELECTROCUTED, GROUND FAULT, E GI V, BATTERY CHARGER
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1251842 | Occupation Not Listed |
Back to Top
Translate