Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1250024.015 - Eas Contracting, Lp

Inspection Information - Office: Fort Worth Area Office

 

Inspection Nr: 1250024.015
Report ID: 0636900
Date Opened: 07/21/2017

Site Address:
Eas Contracting, Lp
Alliance Airport
Fort Worth, TX 76177

Mailing Address:
6013 Co Rd 437, Princeton, TX 75407

Union Status: NonUnion

SIC:

NAICS: 238210/Electrical Contractors


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/21/2017

Emphasis:

Case Closed: 01/03/2018


Related Activity
Type Activity Nr Safety Health
Referral 1240625 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $21,801 $0 $0 $0 $0 $21,801
Current Penalty $0 $0 $0 $13,080 $0 $13,080
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100134 D01 I 12/07/2017 01/08/2018 $5,324 $8,873 $0 I - Informal Settlement  
2. 01002 Other 19100134 D01 III 12/07/2017 01/08/2018 $3,878 $6,464 $0 I - Informal Settlement  
3. 01003 Other 19101200 H01 12/07/2017 01/08/2018 $3,878 $6,464 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 97545.015
Event: 07/13/2017
Worker mixing concrete patch material is sickened

At 3:50 p.m. on July 13, 2017, Employee #1, employed by a construction company, was mixing a batch of Delcrete/Delpatch DSB 1494 A and B, which is used for concrete repair/patching. Employee #1 became ill and experienced respiratory distress. Emergency services were called, and Employee #1 was transported to the hospital, admitted, and treated for respiratory distress due to chemical exposure.

Keywords: Chemical Vapor, Concrete, Construction, Lung, Material Handling, Mixer, Repair, Respiratory

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1250024.015 18 M Hospitalized injury Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close