Powered by GoogleTranslate

Inspection Detail

Quick Link Reference

1233550.015 | 1233550

Case Status: CLOSED

Inspection: 1233550.015 - Baldwin Developement, Llc

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 1233550.015
Report ID: 0953220
Date Opened: 05/01/2017

Site Address:
Baldwin Developement, Llc
6601 Bermuda Road
Las Vegas, NV 89119

Mailing Address:
6935 Aliante Parkway #104-137, Las Vegas, NV 89106

Union Status: NonUnion

SIC:

NAICS: 238910/Site Preparation Contractors


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/06/2017

Emphasis:

Case Closed: 10/12/2017


Related Activity
Type Activity Nr Safety Health
Complaint 1203290 Yes
Inspection 1245572 Yes
Inspection 1241780 Yes
Inspection 1245525 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 97550.015
Event: 04/12/2017
Demolition worker is shocked by live wires in building

At 9:30 a.m. on April 12, 2017, Employee #1, employed by a demolition company, was working at a multi-employer construction site, of a commercial building. He was demolishing a first floor interior wall. Electrical power in the building had not been shut off, and nearby electrical wires had current flowing through them. Employee #1's left arm came into contact with a conduit containing live electrical wires, and he received a shock. Emergency services were called, and Employee #1 was transported to the hospital. He was treated for an electrical shock injury to his left lower arm. During the subsequent investigation, it was determined that the electrical rating for the building was 120 volts/20 amps.

Keywords: Building, Burn, Conduit, Construction, Demolition, Electric Shock, Electrocuted, Shock, Wall, Work Rules

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1233550.015 26 M Non Hospitalized injury Construction trades, n.e.c.

Inspection: 1233550 - Langman Construction Inc

Inspection Information - Office: Peoria Area Office

 

Inspection Nr: 1233550
Report ID: 0524500
Date Opened: 06/05/1984

Site Address:
Langman Construction Inc
38th To 41st Street
Rock Island, IL 61201

Mailing Address:
2424 36th Ave, Rock Island, IL 61201

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Planned

Scope: No Insp/Process Inactive

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference:

Emphasis: L:Trench

Case Closed: 09/30/1986



Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.