Inspection Detail
Inspection: 514918.015 - Cudd Pressure Control, Inc.
Inspection Information - Office: Houston South Area Office
Site Address:
Cudd Pressure Control, Inc.
2450 S. Gulfway Dr.
Port Arthur, TX 77641
Mailing Address:
16701 East Freeway, Channelview, TX 77530
Union Status: NonUnion
SIC:
NAICS: 325180
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/11/2012
Emphasis:
Case Closed: 08/12/2014
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 436350 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 4 | 4 | ||||
| Current Violations | ||||||
| Initial Penalty | $13,600 | $0 | $0 | $0 | $0 | $13,600 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citation Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100132 D01 I | 08/20/2012 | 08/30/2012 | $0 | $5,100 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
| 2. | 01002 | Serious | 19100134 A02 | 08/20/2012 | 08/30/2012 | $0 | $2,550 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
| 3. | 01003A | Serious | 19101200 D05 IV | 08/20/2012 | 08/30/2012 | $0 | $3,400 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
| 4. | 01003B | Serious | 19101200 E01 II | 08/20/2012 | 08/30/2012 | $0 | $0 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
| 5. | 01003C | Serious | 19101200 H01 | 08/20/2012 | 08/30/2012 | $0 | $0 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
| 6. | 01004 | Serious | 19101200 G08 | 08/20/2012 | 08/30/2012 | $0 | $2,550 | $0 | 09/12/2012 | J - ALJ Decision | Citation has been deleted. |
Translate