Powered by GoogleTranslate

Inspection Detail

Inspection: 316213198 - Atlas Pacific Corporation

Inspection Information - Office: San Bernardino District Office

 

Inspection Nr: 316213198
Report ID: 0950633
Date Opened: 08/16/2013

Site Address:
Atlas Pacific Corporation
2803 Industrial Drive
Bloomington, CA 92316

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3339

NAICS: 331419/Primary Smelting and Refining of Nonferrous Metal (except Copper and Aluminum)


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/24/2013

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/11/2015


Related Activity
Type Activity Nr Safety Health
Accident 102868791
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2 4
Current Violations 1 3 4
Initial Penalty $28,800 $0 $0 $1,100 $0 $29,900
Current Penalty $14,400 $0 $0 $270 $0 $14,670
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A04 12/24/2013 01/27/2014 $135 $550 $0 01/10/2014 F - Formal Settlement  
2. 01002 Other 3382 A 12/24/2013 12/27/2013 $135 $550 $0 01/10/2014 F - Formal Settlement  
3. 02001 Other 3328 G 12/24/2013 12/27/2013 $0 $14,400 $0 01/10/2014 F - Formal Settlement  
4. 03001 Serious 3302 B 12/24/2013 03/21/2014 $14,400 $14,400 $0 01/10/2014 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202715876
Event: 07/24/2013
Employee Suffers Burns on Both Legs When Hot Water Sprays

At approximately 4 p.m. on July 24, 2013, Employee #1 and a coworker were working on zinc furnace #2A. The coworker was pouring molten zinc from furnace #2A on to the molds while the employee was picking and removing the zinc ingots from the molds then staging them onto a pallet. The coworker noticed water leaking from a mold jacket and coming down on the floor. Suddenly, a rubber hose at clamp joint #4 blew off spraying hot water and steam on both the employee's legs. The apron protected Employee #1 from the front but not the backside. The employee was transported to an area hospital, where he was treated for first and second degree burn on both legs. Employee #1 remained hospitalized.

Keywords: BURN, LEAK, STEAM, MOLTEN METAL, PALLET, HOT WATER, LEG, ZINC PLATING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 316213198 Hospitalized injury Burn/Scald(Heat) Furnace, kiln and oven operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close