Powered by GoogleTranslate

Inspection Detail

Inspection: 310288832 - Reed Contracting Incorporated

Inspection Information - Office: Pittsburgh Area Office

 

Inspection Nr: 310288832
Report ID: 0317500
Date Opened: 11/09/2006

Site Address:
Reed Contracting Incorporated
288 Lessig Road
Leechburg, PA 15656

Mailing Address:
1303 Gravel Bar Road, Vandergrift, PA 15690

Union Status: NonUnion

SIC:1761

NAICS: 238160/Roofing Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/07/2006

Emphasis: L:Rescon, S:Residential Constr

Case Closed: 08/26/2008


Related Activity
Type Activity Nr Safety Health
Accident 100541176
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $3,750 $0 $0 $0 $0 $3,750
Current Penalty $3,750 $0 $0 $0 $0 $3,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260416 A03 12/19/2006 12/22/2006 $1,500 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260451 F06 12/19/2006 12/22/2006 $1,500 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19260451 G01 I 12/19/2006 12/22/2006 $750 $750 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200541514
Event: 11/08/2006
Employee electrocuted when ladder contacts power line

On November 8, 2006, Employee #1 and a coworker were on two ladder jack scaffolds, using an aluminum ladder hoist for material transport while installing shingles on the face of a two-story detached garage. The company owner had contracted with the homeowner to replace the shingles, gutters, soffit, and fascia. They had finished their work on the front of the building and decided to dismantle the scaffolds and ladder hoist before going to lunch. Concerned about an overhead power line that was approximately 13 ft from the building, they rotated the hoist onto its side rail before standing it straight up, positioning the ladder parallel to the power line. They were walking the hoist down when the top of the ladder contacted the primary line. Both workers sustained electric shocks. The coworker was thrown from the ladder hoist, but Employee #1 remained frozen to it by the current. The owner of the company saw the incident, ran over, and knocked Employee #1 free. He then noticed that Employee #1 was struggling to breathe, so he ran to the house and told the homeowner, who was a nurse, to dial 911. She then came out and administered first aid and CPR. Paramedics arrived shortly thereafter and took over the rescue operations. Employee #1 was transported to a local hospital, where he later died.

Keywords: CLEARANCE, OVERHEAD POWER LINE, DISMANTLING, WORK RULES, ELECTROCUTED, STRUCK AGAINST, CONSTRUCTION, LADDER JACK SCAFFOLD, METAL LADDER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 310288832 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close