Inspection: 308017458 - J&A Heating & Cooling, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 308017458
Report ID: 0352430
Date Opened: 10/01/2004

Site Address:
J&A Heating & Cooling, Inc.
Jesse Boyd Circle, Lot 97
Elkton, MD 21921

Mailing Address:
536 Frist Road, Colora, MD 21917

Union Status: NonUnion

SIC:1711

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/06/2004

Planning Guide: Safety-Construction

Emphasis: S:Falls

Case Closed: 01/31/2005


Related Activity
Type Activity Nr Safety Health
Accident 102356672
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,200 $0 $0 $0 $0 $4,200
Current Penalty $1,100 $0 $0 $0 $0 $1,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19261053 B05 I 11/12/2004 11/17/2004 $500 $1,400 $0 I - Informal Settlement  
2. 01002 Serious 19261053 B07 11/12/2004 11/17/2004 $300 $1,400 $0 I - Informal Settlement  
3. 01003 Serious 19261060 A 11/12/2004 12/15/2004 $300 $1,400 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202353991
Event: 09/29/2004
Employee is injured in fall from ladder

On September 29, 2004, Employee #1, an apprentice, was working in a vocational-technical program. He had erected a ladder at the rear of a dwelling under construction in order to install a bath fan. The top of the ladder was approximately 18 ft above ground level, while the base of the ladder had been placed approximately 10 ft back from the dwelling, at an extreme angle. Ground conditions were muddy, and the ladder was not secured. The ladder slipped, but did not collapse, causing the employee to fall to the soft muddy ground. Employee #1 sustained bruised ribs and was disabled for approximately 6 days.

Keywords: INSTALLING, UNSECURED, LADDER, RIB, FALL, CONTUSION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 308017458 Hospitalized injury Bruise/Contus/Abras Sheet metal worker apprentices
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.