Powered by GoogleTranslate

Inspection Detail

Inspection: 302626510 - The Pietrini Corp. T/A B. Pietrini & Sons

Inspection Information - Office: Osha Philadelphia Area Office

 

Inspection Nr: 302626510
Report ID: 0317000
Date Opened: 02/10/2000

Site Address:
The Pietrini Corp. T/A B. Pietrini & Sons
Rpac
Philadelphia, PA 19102

Mailing Address:
111 East Church Road, King Of Prussia, PA 19406

Union Status: Union

SIC:1771

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/25/2000

Emphasis: S:Construction

Case Closed: 12/12/2001


Related Activity
Type Activity Nr Safety Health
Accident 102020633
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 2 7
Current Violations 5 2 7
Initial Penalty $12,600 $112,000 $0 $0 $0 $124,600
Current Penalty $5,000 $0 $0 $0 $82,000 $87,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260403 B01 08/07/2000 08/10/2000 $900 $1,050 $0 08/16/2000 F - Formal Settlement  
2. 01002 Serious 19260404 F06 08/07/2000 08/10/2000 $900 $1,050 $0 08/16/2000 F - Formal Settlement  
3. 01003 Serious 19260021 B02 08/07/2000 08/24/2000 $1,100 $3,500 $0 08/16/2000 F - Formal Settlement  
4. 01004 Serious 19260703 B05 08/07/2000 08/10/2000 $1,100 $3,500 $0 08/16/2000 F - Formal Settlement  
5. 01005 Serious 19260703 B06 08/07/2000 08/10/2000 $1,000 $3,500 $0 08/16/2000 F - Formal Settlement  
6. 02001 Unclass 19260703 A01 08/07/2000 08/10/2000 $41,000 $56,000 $0 08/16/2000 F - Formal Settlement  
7. 02002 Unclass 19260703 A02 08/07/2000 08/10/2000 $41,000 $56,000 $0 08/16/2000 F - Formal Settlement  

Investigation Summary

Investigation Nr: 202003851
Event: 02/10/2000
Eight employees injured when forms for access ramp collapsed

On February 10, 2000, eight workers were injured when the formwork for a three-story-high concrete vehicle access ramp collapsed. The formwork was constructed without any shop drawings. The PERI formwork system was new to the carpenters who constructed it. In addition, they had received no training on proper erection procedures for the system in a stacked tower configuration. The workers, who were cement finishers, laborers, and an electrician, and were on the ramp formwork at the time of the collapse, sustained various serious injuries when they fell along with the formwork, rebar and 23-yards of freshly placed concrete. By not having the drawings and not being trained, the carpenters assembled a formwork system that was missing up to 50 of the minimum necessary components required by PERI. In addition, the company had created makeshift mudsills that were unstable, due to the use of various components of differing dimensions. The injured workers fell approximately 33 feet, and were hospitalized with concussions, chemical burns, sprains and other injuries.

Keywords: CONCRETE FORM WORK, CONCUSSION, UNTRAINED, BURN, COLLAPSE, FALL, SPRAIN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302626510 Hospitalized injury Concussion Occupation not reported
2 302626510 Hospitalized injury Other Occupation not reported
3 302626510 Hospitalized injury Other Occupation not reported
4 302626510 Hospitalized injury Other Occupation not reported
5 302626510 Hospitalized injury Strain/Sprain Occupation not reported
6 302626510 Hospitalized injury Other Occupation not reported
7 302626510 Hospitalized injury Concussion Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close