Inspection: 300188729 - Nabors Drilling Usa, Inc., Rig #16

Inspection Information - Office: Corpus Christi Area Office

 

Inspection Nr: 300188729
Report ID: 0626000
Date Opened: 09/09/1997

Site Address:
Nabors Drilling Usa, Inc., Rig #16
Thirty (30) Miles West On Fm 766
Gonzales, TX 78629

Mailing Address:
P. O. Box 4629, Victoria, TX 77903

Union Status: NonUnion

SIC:1381

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 09/09/1997

Emphasis: L:Oilgas

Case Closed: 12/15/1998


Related Activity
Type Activity Nr Safety Health
Accident 100210293
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $7,000 $0 $0 $0 $0 $7,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 02/20/1998 02/24/1998 $0 $7,000 $0 03/10/1998 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 200210243
Event: 08/22/1997
Employee killed when struck by flying drill parts

Employee #1, age 20, was working at a vertical drilling mud standpipe alongside the southeast derrick leg. Approximately 55 in. above the drill rig floor, a nipple had been welded near the end of a 4 in. diameter standpipe. A high pressure collar had been screwed onto the threads at the opposite end of the nipple. A second nipple had been screwed into the other end of the high pressure collar. An Oteco 5,000 psi gate valve had been threaded onto the opposite end of this second nipple and another high pressure nipple had been screwed in opposite the gate valve. On the other end of this high pressure nipple had been threaded a high pressure T-joint. A high pressure bull plug had been screwed into the opening at the top of the T, and an employee stated that an open-ended pipe had been screwed into the other end of the T. The first part of this piping configuration, up to the Oteco gate valve, was under 3,250 psig of pressure. A representative of an in-line pressure instrumentation and information company came to the drill rig floor and told Employee #1 that he was going to change the location of the drilling mud pump pressure sensor and that he wanted to move it to where the blank bull plug was located in the high pressure T. The open-ended pipe was removed from the end of the high pressure T. A 36 in. pipe wrench with a cheater pipe was used to remove the bull plug from the top opening in the high pressure T, and it was placed on the end opening. A different bull plug with the new sensor was then screwed into the top opening. The service company representative proceeded to tighten the connection by pulling on the end of the wrench while Employee #1 pushed on it. The configuration of high pressure collar, nipples, gate valve, high pressure T, and bull plug, was blown off of the threads of the high pressure nipple that was directly welded to the drilling mud standpipe. The drill parts struck Employee #1 in the left upper arm. He was killed.

Keywords: DRILL OPERATOR, WORK RULES, OIL WELL DRILLING, HIGH PRESSURE, VALVE, STRUCK BY, ARM, FLYING OBJECT, PRESSURE RELEASE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 300188729 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.