Powered by GoogleTranslate

Inspection Detail

Inspection: 126001270 - Boston Market

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 126001270
Report ID: 0950632
Date Opened: 02/20/1997

Site Address:
Boston Market
706 Fletcher Pkwy
El Cajon, CA 92020

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:5812

NAICS: 0 


Inspection Type: Complaint

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/06/1997

Emphasis:

Case Closed: 07/24/1997


Related Activity
Type Activity Nr Safety Health
Accident 362254096
Complaint 75925099 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 8 8
Current Violations 8 8
Initial Penalty $0 $0 $0 $2,660 $0 $2,660
Current Penalty $0 $0 $0 $2,660 $0 $2,660
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 23400016 C 05/09/1997 05/29/1997 $280 $280 $0 -  
2. 01002 Other 25000008 A 1 05/09/1997 05/21/1997 $420 $420 $0 -  
3. 01003 Other 3219 A 05/09/1997 05/14/1997 $560 $560 $0 -  
4. 01004 Other 3272 B 05/09/1997 05/26/1997 $185 $185 $0 -  
5. 01005 Other 3273 A 05/09/1997 05/29/1997 $280 $280 $0 -  
6. 01006 Other 6151 E 1 05/09/1997 05/21/1997 $185 $185 $0 -  
7. 01007 Other 342 A 05/09/1997 05/15/1997 $375 $375 $0 -  
8. 01008 Other 14305 A 05/09/1997 05/21/1997 $375 $375 $0 -  

Investigation Summary

Investigation Nr: 201060373
Event: 09/25/1996
EMPLOYEE SUFFERS BURN FROM HOT WATER

At approximately 8:15 p.m. on August 25, 1996, Employee #1 was standing near the back preparation area when her foot slipped in between the copper drain pipe and the floor drain. The pipe was discharging hot water from the heating tray at the time. There was an approximately 4 in. gap between the bottom of the pipe and the floor drain cover. The employee was wearing canvas shoes at the time. Employee #1 was hospitalized for two days for burn treatment.

Keywords: BURN, HEAT, SKIN, FOOT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 126001270 Hospitalized injury Burn/Scald(Heat) Food counter, fountain and related occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close