Powered by GoogleTranslate

Inspection Detail

Inspection: 125744771 - Aerojet Fine Chemicals Llc

Inspection Information - Office: Sacramento District Office

 

Inspection Nr: 125744771
Report ID: 0950621
Date Opened: 07/31/2001

Site Address:
Aerojet Fine Chemicals Llc
Bldg 05-046 Aerojet Rd.
Rancho Cordova, CA 95741

Mailing Address:
P.O. Box 1718, Rancho Cordova, CA 95741

Union Status: Union

SIC:2834

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 11/16/2001

Emphasis:

Case Closed: 03/20/2007


Related Activity
Type Activity Nr Safety Health
Accident 361699895
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $22,500 $0 $0 $600 $0 $23,100
Current Penalty $22,500 $0 $0 $600 $0 $23,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5194 F04 11/21/2001 12/10/2001 $600 $600 $0 12/14/2001 J - ALJ Decision  
2. 02001 Serious 5420 A02 11/21/2001 11/27/2001 $22,500 $22,500 $0 12/14/2001 J - ALJ Decision  

Investigation Summary

Investigation Nr: 201171188
Event: 07/19/2001
Employee injured when burned by flash fire while soldering

On July 19, 2001, Employee #1 was torch soldering piping leading to a tank when there was a flash fire. The tank had not been marked with its contents or a warning. It had not been fully drained of a flammable methanol and water solution, had not been flushed or purged, and had not been tested for flammability prior to the soldering. Management had not followed the required procedures or its own written line breaking, hot work permit, and safety work permit procedures. Employee #1 was set on fire and suffered second and third degree burns to his face, neck, arms, abdomen and back. He was treated at a hospital and was sent home the next day, where he was incapacitated for an additional twelve days.

Keywords: BURN, METHYL ALCOHOL, ABDOMEN, SOLDERING TORCH, FIRE, BACK, NECK, ARM, FACE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 125744771 Hospitalized injury Burn/Scald(Heat) Heating, air conditioning, and refrig. mechanics
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close