Powered by GoogleTranslate

Inspection Detail

Inspection: 114610546 - T.B.C Company

Inspection Information - Office: Nv-E-Reno 0953210

 

Inspection Nr: 114610546
Report ID: 0953210
Date Opened: 01/07/1990

Site Address:
T.B.C Company
5500 Soda Lake Road
Fallon, NV 89406

Mailing Address:
743 Horizon Court #333, Grand Junction, CO 81506

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/31/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 01/08/1991


Related Activity
Type Activity Nr Safety Health
Accident 360243018

Investigation Summary

Investigation Nr: 885137
Event: 01/04/1991
Employee burned in fall into pit of scalding water

Employee #1 was approaching a geothermal water pipe that had been leaking, causing a pit to form in the ground. He either walked or slipped into the pit, scalding over 60 percent of his body. He was hospitalized.

Keywords: BURN, LEAK, SLIP, CONSTRUCTION, FALL, WATER PIPE, HIGH TEMPERATURE, HOT WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 114610546 Hospitalized injury Burn/Scald(Heat) Supervisors, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.