Powered by GoogleTranslate

Inspection Detail

Inspection: 112531207 - Warwood Armature Repair Company

Inspection Information - Office: Columbus Area Office

 

Inspection Nr: 112531207
Report ID: 0522500
Date Opened: 08/24/2005

Site Address:
Warwood Armature Repair Company
57246 Ferry Landing Rd.
Shadyside, OH 43947

Mailing Address:
128 N. 7th St., P.O. Box 4008, Wheeling, WV 26003

Union Status: Union

SIC:7694

NAICS: 811310/Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/07/2005

Emphasis:

Case Closed: 11/15/2005


Related Activity
Type Activity Nr Safety Health
Complaint 205441140 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $1,400 $0 $0 $0 $0 $1,400
Current Penalty $980 $0 $0 $0 $0 $980
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100024 H 09/22/2005 10/02/2005 $368 $525 $0 I - Informal Settlement  
2. 01002 Serious 19100269 D08 IV 09/22/2005 10/02/2005 $613 $875 $0 I - Informal Settlement  
3. 01003A Other 19100147 C04 II 09/22/2005 10/25/2005 $0 $0 $0 I - Informal Settlement  
4. 01003B Other 19100147 C06 II 09/22/2005 10/25/2005 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200758118
Event: 07/26/2005
Three Employees Are Burned When Broiler Ruptures

At 9:34 a.m. on July 26, 2005, Employees #1, #2, and #3, of Warwood Armature Repair Company, were performing repair work on the motor of the 5 East induced fan at the First Energy Corp., R.E. Burger Plant. When a boiler tube in boiler Number 5, Unit Number 3 ruptured, it released a large quantity of steam and hot gas from the boiler interior, escaping out of openings into the boiler walls and roof. All three employees sustained steam burns. At the time of the rupture, the boiler was operating with two forced fans and one induced fan running. Employee #1 was hospitalized for six days. The other two employees were treated for steam burns and released.

Keywords: BURN, FAN, PRESSURE VESSEL, RUPTURE, STEAM, OVERHEATED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 112531207 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 112531207 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 112531207 Non Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close