Powered by GoogleTranslate

Inspection Detail

Inspection: 111814422 - East Bay Lawn Mover

Inspection Information - Office: Oakland District Office

 

Inspection Nr: 111814422
Report ID: 0950614
Date Opened: 10/28/1992

Site Address:
East Bay Lawn Mover
725 A Street
Hayward, CA 94541

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:0782

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/19/1993

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 02/15/1994


Related Activity
Type Activity Nr Safety Health
Accident 361333339
Accident 361333354
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 8 10
Current Violations 2 8 10
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $750 $0 $0 $395 $0 $1,145
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203 A 04/19/1993 05/15/1993 $120 $0 $0 A - Amendment  
2. 01002 Other 25000008 A 04/19/1993 05/15/1993 $75 $0 $0 A - Amendment  
3. 01003 Other 3362 A 04/19/1993 05/15/1993 $45 $0 $0 A - Amendment  
4. 01004 Other 5194 E01 04/19/1993 05/15/1993 $90 $0 $0 A - Amendment  
5. 01005 Other 3273 B 04/19/1993 05/15/1993 $65 $0 $0 A - Amendment  
6. 01006 Other 3221 A 04/19/1993 05/15/1993 $0 $0 $0 -  
7. 01007 Other 3220 A 04/19/1993 05/15/1993 $0 $0 $0 -  
8. 01008 Other 14301 A01 04/19/1993 05/15/1993 $0 $0 $0 -  
9. 02001 Serious 5432 A 04/19/1993 10/29/1993 $450 $0 $0 A - Amendment  
10. 03001 Serious 3203 A07 04/19/1993 04/30/1993 $300 $0 $0 A - Amendment  

Investigation Summary

Investigation Nr: 170702930
Event: 10/28/1992
Employee burned in part-cleaning tank explosion and fire

Employee #1 was a mechanic for East Bay Lawn Mower. At approximately 12:10 p.m. on October 28, 1992, a coworker was using the cleaning tank to clean a part. The coworker turned off the tank, left the lid open, and went to the other side of the shop area. The tank, which had been contaminated with gasoline, was ignited by sparks from the nearby grinding operation. Employee #1 closed the lid on the tank. When the employee re-opened the tank's lid, it ignited again and the employee caught fire, severely burning his face, arms, and chest. Spark-producing devices too close to ignition sources caused the explosion. Consequently, citations for a serious violation of T8CCR 5432(a) and a serious violation for insufficient training of employees in the proper use of the dip tank lid in case of fire, T8CCR 3203(a)(7), were issued.

Keywords: BURN, COVER, AGRICULTURE, FIRE, MECHANIC, EXPLOSION, SPARK, GASOLINE, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 111814422 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.