Powered by GoogleTranslate

Inspection Detail

Inspection: 109891333 - Rapid Sewer Cleaners

Inspection Information - Office: Manhattan Area Office

 

Inspection Nr: 109891333
Report ID: 0215000
Date Opened: 09/23/1991

Site Address:
Rapid Sewer Cleaners
5404 Amboy Road
Staten Island, NY 10307

Mailing Address:
109 Westcott Blvd., Staten Island, NY 10307

Union Status: NonUnion

SIC:7699

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/24/1991

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 12/30/1991


Related Activity
Type Activity Nr Safety Health
Accident 361110299
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 2 8
Current Violations 6 2 8
Initial Penalty $4,275 $0 $0 $1,500 $0 $5,775
Current Penalty $3,150 $0 $0 $1,050 $0 $4,200
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/15/1991 12/02/1991 $525 $525 $0 I - Informal Settlement  
2. 01002 Serious 19100304 F04 11/15/1991 12/02/1991 $525 $750 $0 I - Informal Settlement  
3. 01003 Serious 19100305 B02 11/15/1991 12/02/1991 $525 $750 $0 I - Informal Settlement  
4. 01004 Serious 19101200 E01 11/15/1991 12/16/1991 $525 $750 $0 I - Informal Settlement  
5. 01005 Serious 19101200 G08 11/15/1991 12/16/1991 $525 $750 $0 I - Informal Settlement  
6. 01006 Serious 19101200 H 11/15/1991 12/16/1991 $525 $750 $0 I - Informal Settlement  
7. 02001 Other 19030002 A01 11/15/1991 11/18/1991 $0 $0 $0 I - Informal Settlement  
8. 02002 Other 19040008 11/15/1991 11/18/1991 $1,050 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 644989
Event: 09/08/1991
Employee dies when overcome by fumes, falls in septic system

Employee #1 used a ladder to enter a septic tank to unclog a drainage pipe with an electric eel. The clogged pipe was approximately 1 1/2 to 2 ft below the surface cover. The employee was overcome by the fumes and fell face down into the 10 ft deep tank, which contained 18 in. of septic water. When rescued by the fire department/EMS, the employee had no pulse or heartbeat. He did not respond to treatment and was pronounced dead at the hospital.

Keywords: CONFINED SPACE, PPE, FALL, TOXIC FUMES, OVEREXPOSURE, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 109891333 Fatality Other Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close