Powered by GoogleTranslate

Inspection Detail

Inspection: 105756902 - Al Gleeson Electrical Company, Inc.

Inspection Information - Office: Va-E-Manassas (Regional Office)- Safety 0355114

 

Inspection Nr: 105756902
Report ID: 0355114
Date Opened: 04/03/1991

Site Address:
Al Gleeson Electrical Company, Inc.
9550 Burke Road
Burke, VA 22015

Mailing Address:
, , 00000

Union Status: Union

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/04/1991

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 08/24/1992


Related Activity
Type Activity Nr Safety Health
Accident 360304885
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 5 8
Current Violations 3 5 8
Initial Penalty $3,000 $0 $0 $0 $0 $3,000
Current Penalty $2,100 $0 $0 $0 $0 $2,100
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 09/09/1991 09/13/1991 $700 $1,000 $0 09/30/1991 Y - State Decision  
2. 01002 Serious 19260550 A05 09/09/1991 09/13/1991 $700 $1,000 $0 09/30/1991 Y - State Decision  
3. 01003 Serious 19260550 A16 09/09/1991 10/14/1991 $700 $1,000 $0 09/30/1991 Y - State Decision  
4. 02001 Other 19260059 E01 09/09/1991 10/14/1991 $0 $0 $0 09/30/1991 Y - State Decision  
5. 02002 Other 19260059 G08 09/09/1991 10/14/1991 $0 $0 $0 09/30/1991 Y - State Decision  
6. 02003 Other 19260550 A04 09/09/1991 09/19/1991 $0 $0 $0 09/30/1991 Y - State Decision  
7. 02004 Other 19260550 A06 09/09/1991 09/13/1991 $0 $0 $0 09/30/1991 Y - State Decision  
8. 02005 Other 19260550 B02 09/09/1991 09/26/1991 $0 $0 $0 09/30/1991 Y - State Decision  

Investigation Summary

Investigation Nr: 14294821
Event: 04/03/1991
Employee struck and killed by falling headache ball

Employees were preparing to move a light pole. Employee #1 was standing near the base of the light pole. The operator of the Elliott Hi-Reach crane, model #ECE 50, was moving the rigging up the pole. There was no load on the crane, only the headache ball. When the headache ball reached the cross member at the top of the light pole, a height of approximately 30 ft, it detached from the crane cable and fell, striking Employee #1 in the head. He was killed.

Keywords: HEAD, CONSTRUCTION, STRUCK BY, FALLING OBJECT, HEADACHE BALL, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 105756902 Fatality Fracture Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close