Group Sampling Information
Sampling Media Sampling Time
(If there are exceptions they will be in Notes)
TWA Sampling Volume
(If there are exceptions they will be in Notes)
TWA Flow Rate
(If there are exceptions they will be in Notes)
2) Anasorb 747 sampling tubes (6 mm glass tubes, the front tube contains 400 and the back 200 mg of sorbent) connected in series [SKC 226-82] 240 min 12 L 0.05 L/min
Analytes Sampling Information
Analytes IMIS Code Wipe Sampling Incompatibilities
2-Butoxyethanol 0435 No
n-Butyl alcohol 0460 No
sec-Butyl alcohol 0461 No
Ethyl alcohol 1060 No
Isobutyl alcohol 1536 No
Isopropyl alcohol 1560 No
Methyl alcohol* 1660 No
n-Propyl alcohol 2170 No
Notes

Immediately after sampling, separate the two sampling tubes to prevent post-sampling migration.

Request any (up to two (2)) of these analytes together.

Results for unrequested analytes in this group will be reported if significant amounts are found.

There is no need to contact SLTC before sampling.

*If this is your primary analyte of interest, sample for 60 min at 0.05 L/min (3L). If the relative humidity is >50% at 25°C, you can sample for 100 min at 0.05 L/min (5L).