29 CFR 1910.217(g) Mechanical Power Press Point of Operation Injury Reports
8/1994 - 12/2000
| Year | Full/Part | Safety Device | Initiation | Injury | In/Out | M/F | Cause | 
|---|---|---|---|---|---|---|---|
| 1994 (51) (4 mos.) | 34/17 | Barrier 18 Pullout 13 2 hand 11 PSD 2 NS 7 | Foot 35 2 hand 13 Auto 1 NS 1 | Amp. 62* Crush/cut/pinch 23* | 17/18 NS 16 | 37/14 | Accidental trip 29 No safety used 16 Press failure 3 No lockout 1 NS 2 | 
| 1995 (127) | 55/42 NS 30 | 2 hand 41 Barrier 27 Pullout 25 Tools 4 PSD 5 NS 25 | Hand 52 Foot 51 Auto 6 NS 18 | Amp. 132* Crush/cut/pinch 48* Fatal 1 | 50/49 NS 26 | 83/34 NS 10 | Accidental trip 83 No safety used 28 Press failure 11 No lockout 2 NS 3 | 
| 1996 (120) | 57/41 NS 12 | 2 hand 41 Pullout 34 Barrier 31 Tools 9 PSD 9 Block 1 */2 | Foot 66 Hand 41 Auto 6 NS 2 | Amp. 152* Crush/cut/pinch 146* Broken jaw 1 | 56/64 | 72/48 | Accidental Trip 45 No safety used 40 Press failure 21 Safety guard malfunction 10 Struck by material 2 NS 2 | 
| 1997 (127) | 50/72 DD 2 NS 3 | 2 hand 32 Pullout 20 Barrier 49 Tools 2 PSD 12 NS 9 | Foot 66 2 hand 48 PSD 1 Auto 1 Robot 1 NS 10 | Amp. 102* Crush/cut/pinch 58* | 51/30 NS 46 | NS | Removing scrap 42 Safety not used 43 Safety guard malfunction 20 Press failure 17 Accidental trip 10 (Totals include 5 with more than one cause) | 
| 1998 (116) | 47/52 Air 2 Hyd 6 NS 9 | Barrier 37 2 Hand 37 Pullout 22 PSD 9 Tool 3* | Foot 51 2 hand 52 Man 2 Auto 3 NS 8 | Amp 110* Crush 24 Fracture 12 Laceration 10 Pinch/Bruise 6 NS 2 | 36/55 Auto 6 NS 19 | 58/35 NS 19 | Accidental trip HID to get stuck part 40 Safety not used 28 Press malfunction 15 By passed safety 13 Unknown 4 Other (part struck operator, second operator tripped initiation, not job assignment) 6 | 
| 1999 (104) | 44/44 Air 5 NS 7 Dir 4 | Barrier 41 2 Hand 28 Pullouts 23 None 2 PSD 10 | 2 hand 41 Foot 50 NS 9 Auto 4 | Amp 104* Crush 20 Fracture 10 Laceration 15 | 31/27 Auto 6 NS 40 | 60/31 NS 13 | Accidental trip HID 61 Safety not used 31 Safety malfunction 2 Injured on feed 1 Repeat of press 9 | 
| 2000 (109) | 46/45 NS 17 DD 1 | 2 Hand 35 Pullout 28 Barrier 27 PSD 10 Switch 2 Lockout 1 None 6 | Foot 48 2 Hand 42 Auto 3 PSD 2 NS 14 | Amp. 116* Crush 17 Fractures 15 Lacerations 8 Struck by 1 NS 3 | 43/40 NS 26 | 62/26 NS 21 | Accidental trip HID 40 Safety Not used 34 By passed safety 16 Repeat of press 8 Safeguard failure or not adjusted 7 Brake failure 2 Cause unknown 2 | 
- NS: not specified
- Full/Part: revolution of power press
		- DD: direct drive
 
- Safety Device: barrier guard, pullout or pullback device, 2 hand control button, presence sensing device (PSD)
- Initiation: foot pedal, 2 hand control buttons, automatic
- Injury: */1 Amputation of finger(s) (calculated by finger, i.e. tip = 1, hand = 5), crush, fracture, laceration, pinch
- In/Out: Hands in the die or out of the die operations
- M/F: male/female operator
- Cause: accidental tripping of foot pedal or hand control, failure or repeat of press, no safeguard in use (*/2 More than one cause or safety device)
- MOST FREQUENT CAUSE OF INJURY IS ACCIDENTAL TRIP WHILE HANDS ARE IN DIE.
- 771 Fingers are missing since August of 1994
A request has been made to identify the states the reports are received from, the following is a list of the states: OH-28, WI-11, IL-10, MO-6, PA-6, TX-5, NY-4, NJ-4, TN-3, CT-3, RI, ALA, NE, GA, and MS all had 2. NC, OK, SC, AR, MD, MI, KS, IN and FLA all had one injury report.