For workplace safety and health, please call 800-321-6742; for mine safety and health, please call 800-746-1553; for Job Corps, please call 800-733-5627 and for Wage and Hour, please call 866-487-9243 (866-4-US-WAGE). This website is currently not being updated due to the suspension of Federal government services. The last update to the site was 10/1/2025. Updates to the site will start again when the Federal government resumes operations.
2,4,5-TRICHLOROPHENOXYACETIC ACID (2,4,5-T)†
| CAS # | 93-76-5 |
|---|---|
| Formula |
C₈H₅Cl₃O₃ |
| Synonyms |
2,4,5-T |
| Physical description | Colorless to tan, odorless, crystalline solid. | ||
|---|---|---|---|
| Boiling point | decomposes | Molecular weight | 255.5 |
| Freezing point/melting point | 316°F | Vapor pressure | 1x10-7 mmHg |
| Flash point | Vapor density | ||
| Specific gravity | 1.8 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 2324 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | GFF (37 mm), Type A/E [AP4003705] |
| Sampling time* | |
| Sampling volume (TWA)* | 15 L-200 L |
| Sampling flow rate (TWA)* | 1-3 L/min |
| Sampling volume (STEL/Peak/C)* | |
| Sampling flow rate (STEL/Peak/C)* | |
| Analytical method instruments | HPLC |
| Method reference | NIOSH 5001 (OSHA modified) |
| Notes | |
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
|
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
10 mg/m³ |
REL-TWA |
10 mg/m³ |
TLV-TWA |
10 mg/m³ [1992] |
PEL-TWA |
10 mg/m³ |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
|
TLV-C |
|
PEL-C |
|
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: |
Notes:
|
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH | ||||||
| Carcinogenic classifications: IARC-2B, TLV-A4 |
Notes:
|
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - 2,4,5-Trichlorophenoxyacetic acid NIOSH: Pocket Guide to Chemical Hazards - 2,4,5-T Literature References
|
Last Updated Date : 01/29/2021