For workplace safety and health, please call 800-321-6742; for mine safety and health, please call 800-746-1553; for Job Corps, please call 800-733-5627 and for Wage and Hour, please call 866-487-9243 (866-4-US-WAGE). This website is currently not being updated due to the suspension of Federal government services. The last update to the site was 10/1/2025. Updates to the site will start again when the Federal government resumes operations.
METHOXYCHLOR†
| CAS # | 72-43-5 |
|---|---|
| Formula |
C₁₆H₁₅Cl₃O₂ |
| Synonyms |
p,p'-dimethoxydiphenylftrichloroethane; DMDT; methoxy-DDT; 2,2-bis(p-methoxyphenyl)-1,1,1-trichloroethane; 1,1,1-trichloro-2,2-bis-(p-methoxyphenyl)ethane |
| Physical description | Colorless to light-yellow crystals with a slight, fruity odor. | ||
|---|---|---|---|
| Boiling point | decomposes | Molecular weight | 345.7 |
| Freezing point/melting point | 171°F | Vapor pressure | Very low |
| Flash point | Vapor density | 12 | |
| Specific gravity | 1.41 | Ionization potential | |
| Lower explosive limit (LEL) | Upper explosive limit (UEL) | ||
| NFPA health rating | NFPA fire rating | ||
| NFPA reactivity rating | NFPA special instruction | ||
| Vapor hazard ratio (VHR) | |||
| Historical exceedance percentage | |||
| Target organs | |||
| Analyte code (IMIS no.) | 1646 |
|---|---|
| Sampling group | |
| Sampler/Sampling media | OSHA versatile sampler (OVS-2) - 13 mm XAD-2 tube (270/140 mg) with GFF enclosed [SKC 226-30-16] |
| Sampling time* |
|
| Sampling volume (TWA)* |
60 L |
| Sampling flow rate (TWA)* |
1 L/min |
| Sampling volume (STEL/Peak/C)* |
|
| Sampling flow rate (STEL/Peak/C)* |
|
| Analytical method instruments | GC-ECD |
| Method reference | OSHA PV2038 (partially validated) |
| Notes |
|
| Special requirements |
|
* All sampling instructions above are recommended guidelines for OSHA Compliance Safety and Health Officers (CSHOs), please see the corresponding OSHA method reference for complete details.
| Wipe Sampler/Sampling media |
|
|---|---|
| Bulk Method |
Limit the amount of bulk submitted to 1 g or 1 mL. |
| Device | |||||
|---|---|---|---|---|---|
| Model/Type | |||||
|
Sampling information (see manufacturer instructions) |
|
OSHA PEL
8-hour TWA (ST) STEL (C) Ceiling Peak |
NIOSH REL
Up to 10-hour TWA (ST) STEL (C) Ceiling |
ACGIH TLV©
8-hour TWA (ST) STEL (C) Ceiling |
|||||
|---|---|---|---|---|---|---|---|
| PEL-TWA |
15 mg/m³ (total dust) |
REL-TWA |
|
TLV-TWA |
10 mg/m³ [1992] |
PEL-TWA |
10 mg/m³ |
| PEL-STEL |
|
REL-STEL |
|
TLV-STEL |
|
PEL-STEL |
|
| PEL-C |
|
REL-C |
|
TLV-C |
|
PEL-C |
|
| Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
Skin notation |
N |
| Notes: |
Notes:
CARCINOGEN (Ca): REDUCE EXPOSURE TO LOWEST FEASIBLE CONCENTRATION. (LOQ 0.07 mg/m³) See Appendix A, NIOSH Potential Occupational Carcinogens. |
Notes:
|
Notes:
|
||||
| Health factors: See NIH-NLM PubChem. | IDLH |
5000 mg/m³ |
|||||
| Carcinogenic classifications: IARC-3, NIOSH-Ca, TLV-A4, EPA-D |
Notes:
Ca |
||||||
|
AIHA emergency response planning guidelines - ERPG-1/ERPG-2/ERPG-3:
|
|||||||
Additional Resources and Literature References
|
NOAA: CAMEO Chemicals - Methoxyclor NIOSH: Pocket Guide to Chemical Hazards - Methoxyclor Literature References
|
Last Updated Date : 01/05/2021