|
Tetramethyltin
| Method number: | PV2057 |
| |
| Matrix: | Air |
| |
| Target concentration: |
The OSHA PEL for tin (organic compounds) measured as total tin is 0.1 mg/cu m. |
| |
| Procedure: |
Samples are collected by drawing a known volume of air
through a charcoal tube. Samples are desorbed with carbon disulfide
and analyzed by gas chromatography with a flame ionization detector (GC-FID). |
| |
| Air volume and sampling rate studied: |
20 liters at 0.2 Lpm |
| |
| Status of method: |
Stopgap method. This method has been only partially
evaluated and is presented for information and trial use. |
| |
| Date: November, 1988 |
Chemist: Mary E. Eide |
SOLVENTS BRANCH
OSHA ANALYTICAL LABORATORY
SALT LAKE CITY, UTAH
1. General Discussion
1.1. Background
1.1.1. History of procedure
The OSHA Laboratory received samples collected on charcoal tubes lot 120
requesting analysis for tetramethyltin (TMT). A write-up describing a
charcoal tube procedure was submitted with the air samples. There was no
information on desorption or retention efficiencies so a further evaluation
was undertaken. The most common solvent for desorbing charcoal tubes is
carbon disulfide. This solvent was tried and the desorption efficiency was
100%. Retention studies showed breakthrough at 30 liters humid air (91% RH),
so a recommended air volume of 20 liters is used in this study.
1.1.2. Potential workplace exposure (Ref 5.1.)
Tetramethyltin is used as an intermediate in manufacturing.
1.1.3. Toxic Effects (This section is for information purposes and should
not be taken as the basis for OSHA policy. )(Ref 5.2.)
Tetramethyltin exposure has the following effects at low concentrations:
headaches, visual defects, depression, cerebral swelling, reversible
paralysis, unconsciousness, and hypoglycemia.
1.1.4. Physical properties (Ref 5.1. and 5.3.):
| Compound: | (CH3)4Sn |
| Molecular weight: | 178.83 |
| Density: | 1.297 |
| Freezing point: | -54°C |
| Boiling point: | 74°C |
| Flash point: | -12°C (9°F) |
| Color: | colorless liquid |
| Gravimetric factor: | 0.6637 |
| CAS: | 594-27-4 |
| IMIS: | 2431 (organic tin compounds) |
| RTECS: | 78608 (WH8630000) |
1.2. Limit defining parameters
1.2.1. The detection limit of the analytical procedure is 0.05188 µg
tetramethyltin (0.03443 ug tin).This is the smallest amount that could be
detected under the operating conditions used in this study.
1.2.2. The overall detection limit is 0.00172 mg(Sn)/m3 based on a 20 liter
air volume. All air concentrations in this study will be based on a 20 liter
air volume.
1.3. Advantages
1.3.1. The sampling procedure is convenient.
1.3.2. The analytical method is reproducible and sensitive.
1.3.3. Reanalysis of samples is possible.
1.3.4. It may be possible to analyze other compounds at the same time.
1.3.5. Interferences may be avoided by proper selection of column and GC
parameters.
1.4. Disadvantages
For lower air concentrations a larger air sample should be taken, with two
tubes in series, or with a larger sampling tube.
2. Sampling procedure
2.1. Apparatus
2.1.1. A calibrated personal sampling pump, the flow of which can be
determined within + 5% at the recommended flow.
2.1.2. Charcoal tubes, lot 120, containing 100 mg
adsorbing section with a 50 mg backup section
separated by a 2 mm portion of urethane foam,
with a silanized glass wool plug before the
adsorbing section and a 3 mm plug of urethane
foam at the back of the backup section. The ends
are flame sealed and the glass tube containing
the adsorbent is 7 cm long, with a 6 mm O.D. and
4 mm I.D., SKC tubes or equivalent.
2.2. Sampling technique
2.2.1. The ends of the charcoal tube are opened immediately before
sampling.
2.2.2. Connect the charcoal tube to the sampling pump with flexible
tubing.
2.2.3. Tubes should be placed in a vertical position to minimize channeling,
with the smaller section towards the pump.
2.2.4. Air being sampled should not pass through any hose or tubing before
entering the charcoal tube.
2.2.5. Seal the charcoal tube with plastic caps immediately after sampling.
Seal each sample lengthwise with OSHA Form-21 sealing tape.
2.2.6. With each batch of samples, submit at least one blank tube from the
same lot used for samples. This tube should be subjected to exactly the
same handling as the samples (break ends, seal, & transport) except that
no air is drawn through it.
2.2.7. Transport the samples (and corresponding paperwork) to the lab for
analysis.
2.2.8. Bulks submitted for analysis must be shipped in a separate container
from the samples.
2.3. Desorption efficiency
Six tubes were liquid spiked at each loading of tetramethyltin of 0.3113 µg
(0.2066µg tin or 0.01033 mg/m3 tin), 1.297 µg (0.8608 µg tin or
0.04304 mg/m3 tin), 3.113 µg (2.066 µg tin or 0.133 mg/m3 tin), 6.395 µg
(4.304 µg tin or 0.2152 mg/m3 tin), and 12.97 µg (8.608 µg tin or 0.4304 mg/m3
tin). They were allowed to equilibrate overnight at room temperature.
They were opened, each section placed into a separate 2 mL vial, desorbed with
1 mL of the desorbing solution, desorbed for 30 minutes with
occasional shaking, and were analyzed by GC-FID. The overall average was
100 %. (Table 1)
Table 1 Desorption Efficiency
|
| Tube | | % Recovered TMT (µg tin) | |
| # | 0.3113µg | 1.297µg | 3.113µg | 6.395µg | 12.97µg |
| (0.2066µg) | (0.8608µg) | (2.066µg) | (4.244µg) | (8.608µg) |
|
| 1 | 102 | 99.5 | 100 | 101 | 93.6 |
| 2 | 103 | 99.0 | 96.0 | 102 | 101 |
| 3 | 104 | 99.6 | 96.6 | 101 | 101 |
| 4 | 97.0 | 99.5 | 102 | 102 | 101 |
| 5 | 102 | 99.5 | 101 | 102 | 101 |
| 6 | 100 | 100 | lost | 101 | 101 |
| average | 101 | 99.5 | 99.1 | 102 | 99.8 |
| overall |
|
| average | 100 |
|
| standard | |
| deviation | ± 2.22 | |
|
2.4. Retention efficiency
Twelve tubes were liquid spiked with 12.97 µg tetramethyltin (0.4304 mg/m3
tin), allowed to equilibrate overnight, and had 10, 20, 30, and 40 liters
humid air (91% RH) pulled through them. They were opened, desorbed and
analyzed by GC-FID. There was tetramethyltin found on the backup portions of
the 30, and 40 liter samples, so a recommended air volume of 20 liters was
chosen (Table 2). The retention efficiency averaged 99.8%.
Table 2 Retention Efficiency
|
| Liters | % Recovered | % Recovered | Total |
| drawn | 'A' | 'B' | |
|
| 10 | 101 | 0 | 101 |
| 10 | 101 | 0 | 101 |
| 10 | 101 | 0 | 101 |
| 20 | 101 | 0 | 101 |
| 20 | 99.2 | 0 | 99.2 |
| 20 | 99.5 | 0 | 99.5 |
| 30 | 92.9 | 5.8 | 98.7 |
| 30 | 91.8 | 6.0 | 97.8 |
| 30 | 94.1 | 4 | 98.1 |
| 40 | 90.9 | 10.1 | 101 |
| 40 | 92.6 | 8.2 | 101 |
| 40 | 89.3 | 9.5 | 98.8 |
| average | | 99.8 |
|
2.5. Storage
Charcoal tubes were spiked with 3.113 µg tetramethyltin (2.066 µg tin or
0.1033 mg/m3) and 12.97 µg tetramethyltin (8.608 µg tin or 0.4304 mg/m3)
and stored at room temperature until opened and analyzed. The
recoveries averaged 99.2% for the 12 days stored. (Table3)
Table 3 Storage Study
|
| Day | % Recovered | % Recovered |
| 3.113 µg TMT | 12.97 µg TMT |
| (2.066 ug Sn) | (8.608 ug Sn) |
|
| 5 | 102 | 99.6 |
| 5 | 102 | 101 |
| 5 | 102 | 102 |
| 12 | 99.2 | 98.8 |
| 12 | 92.9 | 97.1 |
| 12 | 97.3 | 96.6 |
| average | 99.2 | 99.2 |
|
2.6. Precision
The precision was calculated using the area counts from six injections of
each standard at concentrations of 0.3113 µg/mL TMT (0.2066 µg/mL tin), 1.557
µg/mL TMT (1.033 µg/mL tin), 3.113 µg/mL TMT (2.066 µg/mL tin), and 6.226
µg/mL TMT (4.132 µg/mL tin) (Table 5).
Table 5
|
| µg/mL tetramethyltin (µg/mL tin) |
| Injection | 0.3133 | 1.557 | 3.113 | 6.226 |
| Number | (0.2066) | (1.033) | (2.066) | (4.132) |
|
| 1 | 781 | 2539 | 4770 | 9192 |
| 2 | 783 | 2516 | 4761 | 9130 |
| 3 | 755 | 2521 | 4769 | 9229 |
| 4 | 764 | 2545 | 4768 | 9141 |
| 5 | 765 | 2564 | 4768 | 9177 |
| 6 | 797 | 2546 | 4768 | 9161 |
| Average | 744 | 2539 | 4756 | 9172 |
| Standard | |
| Deviation | ± 15.5 | 17.7 | 28.8 | 36.1 |
| CV | 0.02083 | 0.006971 | 0.006056 | 0.003936 |
| Pooled CV | 0.01155 | |
|
where:
A(1), A(2),A(3),A(4) = # of injections at each level
CVl, CV2, CV3, CV4 = Coefficients at each level
2.7. Air volume and sampling rate studied
2.7.1. The air volume studied is 20 liters
2.7.2. The sampling rate studied is 0.2 liters per minute.
2.8. Interferences
Suspected interferences should be listed on sample data sheets.
2.9. Safety precautions
2.9.1. Sampling equipment should be placed on an employee in a manner that
does not interfere with work performance or safety.
2.9.2. Safety glasses should be worn at all times.
2.9.3. Follow all safety practices that apply to the workplace being
sampled.
3. Analytical method
3.1. Apparatus
3.1.1. Gas chromatograph equipped with a flame ionization detector, a HP 5840
was used in this study.
3.1.2. GC column capable of separating the analyte and an internal standard
from any interferences. The column used in this study was a stainless steel 10
ft. 20% SP2100 0.1% Carbowax 1500 on 100/120 mesh Supelcoport.
3.1.3. An electronic integrator or some other suitable method of measuring
peak areas.
3.1.4. Two milliliter vials with Teflon-lined caps.
3.1.5. A 10 uL syringe or other convenient size for sample injection.
3.1.6. Pipets for dispensing the desorbing solution. The Glenco 1 mL
dispenser was used in this method.
3.1.7. Volumetric flasks - 10 mL and other convenient sizes for preparing
standards.
3.2 Reagents
3.2.1. Purified GC grade nitrogen, hydrogen, and air.
3.2.2. Tetramethyltin, Reagent grade
3.2.3. Carbon disulfide, Reagent grade. In the carbon disulfide used in this
study, there was a small amount of benzene as a contaminant, and this benzene
was used as an internal standard.
3.3. Sample preparation
3.3.1. Sample tubes are opened and the front and back section of each tube
are placed in separate 2 mL vials.
3.3.2. Each section is desorbed with 1 mL of carbon disulfide.
3.3.3. The vials are sealed immediately and allowed to desorb for 30 minutes
with occasional shaking.
3.4. Standard preparation
3.4.1. Standards are prepared by diluting a known quantity of tetramethyltin
with carbon disulfide. An analytical standard of 1 µL TMT/25 mL
carbon disulfide is 51.88 µg TMT/mL (34.43 µg tin/mL). A 1 mL/10 mL dilution
of this standard is 5.188 µg/mL TMT (3.443 µg tin or 0.1722 mg/m3).
3.4.2. At least two separate stock standards should be made, and dilutions
made from both. A low and a high standard should be run to check
the calibration.
3.5. Analysis
3.5.1. Gas chromatograph conditions.
| Flow rates (mL/min) | Temperature (°C) |
| Nitrogen: | 27 | Injector: | 150 |
| Hydrogen: | 30 | Detector: | 200 |
| Air: | 240 | Column: | 70 |
| Injection size: | 2 µL | |
| Elution time: | 4.67 min | |
| Chromatogram: | (See Figure 1) | |
3.5.2. Peak areas are measured by an integrator or other suitable
means.
3.6. Interferences (analytical)
3.6.1. Any compound having the general retention time of the analyte or the
internal standard used is an interference. Possible interferences should
be listed on the sample data sheet. GC parameters should be adjusted if
necessary so these interferences will pose no problems.
3.6.2. Retention time data on a single column is not considered proof of
chemical identity. Samples over the target concentration should be
confirmed by GC/Mass Spec or other suitable means.
3.7. Calculations
3.7.1. To convert mass of tetramethyl tin to mass of tin multiply by the gravimetric factor 0.6637.
3.7.2. To calculate the concentration of analyte in the air sample the following formulas are used:
(µg/m) (desorption volume) (desorption efficiency) |
= mass of analyte in sample |
(mass of analyte in sample) molecular weight |
= number of moles of analyte |
(number of moles of analyte) |
(molar volume at 25°C & 760mm) |
= |
volume the analyte will occupy at 25°C & 760mm |
(volume analyte occupies) (106)* (air volume) |
= ppm |
* All units must cancel.
3.7.3. The above equations can be consolidated to form the following
formula. To calculate the ppm of analyte in the sample based on a 10 liter air sample:
(µg/mL)(DV)(24.45)(106) (10 L)(DE)(MW) |
× |
(g) (1000 mg) |
× |
(mg) (1000 µg) |
= ppm |
| µg/mL | = | concentration of analyte in sample or standard |
| 24.45 | = | Molar volume (liters/mole) at 25° and 760 mm Hg. |
| MW | = | Molecular weight (g/mole) |
| DV | = | Desorption volume |
| 10 L | = | 10 liter air sample |
| DE | = | Desorption efficiency |
3.7.4. This calculation is done for each section of the sampling tube and the
results added together.
3.8. Safety precautions
3.8.1. All handling of solvents should be done in a hood.
3.8.2. Avoid skin contact with all solvents.
3.8.3. Wear safety glasses at all times.
4. Recommendations for further study
Collection studies need to be performed. A better detection limit may be
obtained by using a capillary column for analysis.
Figure 1. A standard of 12.97 µg tetramethyltin/mL carbon disulfide.
5. References
5.1. Grayson, M., "Kirk Othmer Encyclopedia of Chemical Technology", Third Edition, John Wiley & Son, N.Y., 1981, Vol. 16, p. 574.
5.2. Grayson, M., "Kirk Othmer Encyclopedia of Chemical Technology", Third Edition, John Wiley & Son, N.Y., 1981, Vol. 16, p. 578.
5.3. Sweet, D., "Registry of Toxic Effects of Chemical Substances",
1985-86 Edition, U.S. Department of Health and Human Services, Public Health
Service, Center for Disease Control, NIOSH, 1987, Vol. 2, p. 1205.
|