|
Tetraethyltin
| Method number: |
110 |
| Matrix: |
Air |
| Target concentration: |
0.2 mg/m3, TWA |
| Procedure: |
Samples are collected by drawing known volumes of air through
sampling tubes containing 100 mg of XAD-7 in the front section and 50 mg
in the back section. Samples are desorbed with carbon disulfide and
analyzed by GC using an FID detector. |
| Recommended air volume and sampling rate: |
48 L at 0.2 L/min |
| Reliable quantitation limit: |
14.4 µg/m3 |
| Standard error of estimate at target concentration: |
6.13% |
| Status of method: |
Evaluated method. This method has been subjected to
the established evaluation procedures of the Organic Methods Evaluation
Branch. |
| Date: July 1997 |
Chemist: Yihlin Chan |
Organic Methods Evaluation Branch
OSHA Salt Lake Technical Center
Salt Lake City, UT 84115-1802
1. General Discussion
1.1 Background
1.1.1 History
The OSHA PEL for tin is 0.1 mg/m3 for organic tin compounds
and 2 mg/m3 for inorganic tin compounds. (Ref. 5.1) In order to evaluate the exposure
to tin in the workplace, one must distinguish between the organic and the
inorganic tin compounds. The early NIOSH method for organotins (Ref. 5.2),
in which the workplace air is sampled with a membrane filter/charcoal tube
and analyzed by colorimetry, does not do this. Until a satisfactory
procedure for separating the organic tin compounds as a group from the
inorganic ones is found, the specific organotins must be sampled and
analyzed if we were to assess the worker exposure to organotin properly.
The latest NIOSH method for organotin compounds (Ref. 5.3) specifies
sampling with a glass fiber filter/XAD-2 sorbent tube, desorption with
acetic acid/acetonitrile, and analysis with HPLC and graphite furnace
atomic absorption spectrometer. In this procedure, specific organotin
compounds are used for calibration. The method, however, may not be
suitable for volatile tetraethyltin and tetramethyltin.
Although this method covers only tetraethyltin, the original goal of
this work was to provide a common procedure for tetramethyltin and
tetraethyltin. These volatile alkyltins lend themselves well for GC
analysis. Detection using an atomic emission detector was considered
first for its specific measurement of tin, but was abandoned due to lack
of sensitivity. A flame ionization detector was found to provide adequate sensitivity.
A variety of sorbents were considered for a common sampler for
tetramethyltin and tetraethyltin but none of them was satisfactory.
Satisfactory recovery of tetraethyltin was not obtained from charcoal,
carbon molecular sieve, or Anasorb 747, even with a variety of desorption
solvents, including toluene, acetone, methylene chloride/methanol, and
dimethyl-formamide/carbon disulfide. Polymeric sorbents such as Tenax,
XAD-2, and XAD-7, on the other hand, do not collect tetramethyltin well.
A common sampler for these two analytes was never found. XAD-7 was
selected for sampling tetraethyltin because of its high capacity and
ease of handling; it is not as prone to static electricity as XAD-2. An
adequate sampler for tetramethyltin was never found. The best sampler
candidate for tetramethyltin was Anasorb 747 until tests indicated the
sampler capacity to be unacceptably sensitive to humidity. There was no
breakthrough in six hours at 80% RH and 22°C, but at 80% RH and
25°C the 5% breakthrough point was reached in 41 minutes.
This method covers the sampling and analytical procedure for tetraethyltin.
Samples are collected on XAD-7, desorbed with carbon disulfide, and
analyzed by GC/FID.
1.1.2 Toxic effects (This section is for information only and should not
be taken as the basis of OSHA policy.) (Ref. 5.2)
Organotin compounds differ in the severity of their toxic effects as well
as in the organs they affect. The trialkyltins are the most toxic group,
followed by the dialkyltins and monoalkyltins. The tetraalkyltins are
metabolized to their trialkyltin homologs, so that their effects are
those of the trialkyltins, with severity dependent upon the rate of
metabolic conversion. Thus, an important feature of tetraalkyltin
poisoning is the slow development of toxic symptoms and the long periods
before death may occur.
In 1951, Zeman and others reported four cases of employee exposure to
unknown concentrations of tetramethyltin and tetraethyltin. Initial
symptoms in all four subjects included severe headaches and nausea,
with vomiting in two instances. Illnesses lasted four to ten weeks. In
the most severe case of organotin poisoning, bradycardia, hypotension,
and abrupt variations in the sinus rhythm of the heart were observed.
These findings suggest that these organotins are potent poisons of the
circulatory system and may affect the autonomic nervous system.
1.1.3 Workplace exposure
Tetraethyltin is used as a catalyst and as a metal plating agent. It
is also used in flame resistant polyester. (Ref. 5.2) Workers employed
in the manufacturing operations involving tetraethyltin or its application
have the greatest potential for exposure.
1.1.4 Physical properties and other descriptive information (Ref. 5.2)
| CAS no.: |
597-64-8 |
| synonyms: |
tetraethylstannane; TET; TeET |
| molecular formula: |
(C2H5)4Sn |
| formula wt: |
234.94 |
| appearance: |
clear liquid |
| boiling point: |
180.5 - 181°C |
| melting point: |
-136 to -125°C |
| specific gravity: |
1.187 |
| flash point: |
53°C |
| solubility: |
soluble in organic solvents, very slightly soluble in water |
| structure formula: |
 |
The analyte air concentrations throughout this method are based on the
recommended sampling and analytical parameters. The analyte concentrations
are listed as those of tetraethyltin. To compare the concentration to
the OSHA PEL for tin in organic compounds (0.1 mg/m3), apply a conversion
factor of 0.5052 to find the tin content.
1.2 Limit defining parameters
1.2.1 Detection limit of the analytical procedure
The detection limit of the analytical procedure is 4.8 pg. This is the
amount of analyte that will give a response that is significantly
different from the background response of reagent blank. (Sections
4.1 and 4.2)
1.2.2 Detection limit of the overall procedure
The detection limit of the overall procedure is 0.21 µg per sample
(4.3 µg/m3). This is the amount of analyte spiked on the sampler that
will give a response that is significantly different from the background
response of a sampler blank. (Sections 4.1 and 4.3)
1.2.3 Reliable quantitation limit
The reliable quantitation limit is 0.69 µg per sample
(14.4 µg/m3). This
is the amount of analyte spiked on a sampler that will give a signal that
is considered the lower limit for precise quantitative measurements.
(Section 4.4)
1.2.4 Precision (analytical procedure)
The precision of the analytical procedure, measured as the pooled relative
standard deviation over a concentration range equivalent to 0.5 to 2 times
the target concentration, is 1.11%. (Section 4.5)
1.2.5 Precision (overall procedure)
The precision of the overall procedure at the 95% confidence level for
the ambient temperature 15-day storage test (at the target concentration)
is ±12.0%. This includes an additional 5% for sampling error. (Section
4.6)
1.2.6 Recovery
The recovery of tetraethyltin from samples used in a 15-day storage test
remained above 88.1%, when the samples were stored at ambient temperature.
(Section 4.7)
1.2.7 Reproducibility
Six samples, collected from a controlled test atmosphere, with a draft
copy of this procedure, were submitted for analysis by an SLTC Organic
Service Branch. The samples were analyzed after 2 days of storage at
5°C. No individual sample result deviated from its theoretical
value by more than the precision reported in Section 1.2.5. (Section 4.8)
2. Sampling Procedure
2.1 Apparatus
2.1.1 A personal sampling pump calibrated to ±5% of the recommended flow
rate with the sampling device attached.
2.1.2 Glass sampling tubes (110 mm x 6 mm o.d.) packed with two sections
of XAD-7. The front section contains 100 mg and the back section contains
50 mg. The sections are held in place with glass wool plugs. For this
evaluation, commercially prepared sampling tubes were purchased from SKC,
Inc. (Catalog no. 226-95).
2.2 Reagents
None required.
2.3 Technique
2.3.1 Immediately before sampling, break off the ends of the sampling
tube. All tubes should be from the same lot.
2.3.2 Attach the sampling tube to the sampling pump with flexible tubing.
2.3.3 Air should not pass through any hose or tubing before entering the
sampling tube.
2.3.4 Cap both ends after sampling. Wrap each sample with a Form OSHA-21
seal.
2.3.5 Record the air volume for each sample.
2.3.6 Submit at least one blank with each set of samples. Blanks should
be handled in the same manner as samples, except no air is drawn through
them.
2.3.7 List any compounds that could be considered potential interferences.
2.4 Sampler capacity
The capacity of the front section of the XAD-7 tube was tested by sampling
from a test atmosphere of tetraethyltin (0.4 mg/m3, 80% RH,
22°C)
at 0.2 L/min. There was no breakthrough in 8 hours. (Section 4.9)
2.5 Desorption efficiency
2.5.1 The average desorption efficiency for tetraethyltin from XAD-7 over
the range of 0.5 to 2.0 times the target concentration was 102.6%.
(Section 4.10.1)
2.5.2 The desorption efficiencies at 0.2, 0.1, and 0.05 times the target
concentration were found to be 100.2%, 104.0%, and 100.3%, respectively.
(Section 4.10.1)
2.5.3 Desorbed samples remain stable for at least 24 h. (Section 4.10.2)
2.6 Recommended air volume and sampling rate
2.6.1 The recommended air volume is 48 L at 0.2 L/min.
2.6.2 For short-term sampling the recommended air volume is 3 L at 0.2
L/min.
2.6.3 When short-term samples are collected, the air concentrations
equivalent to the reliable quantitation limits become larger. For example,
the reliable quantitation limit is 0.230 mg/m3 for tetraethyltin when
3 L is collected.
2.7 Interferences (sampling)
There is no known interference for sampling.
2.8 Safety precautions (sampling)
2.8.1 The sampling equipment should be attached to the worker in such a
manner that it will not interfere with work performance or safety.
2.8.2 All safety practices that apply to the work area being sampled
should be followed.
3. Analytical Procedure
3.1 Apparatus
3.1.1 A GC equipped with a flame ionization detector. An HP 5890
equipped with a flame ionization detector and an autosampler were used
in this evaluation.
3.1.2 A capillary column capable of separating tetraethyltin and p-cymene
from any interferences. An RTx-1 column (60 m x 0.32 mm i.d., df 1.0 µm)
was used in this evaluation.
3.1.3 An electronic integrator or other suitable means of measuring
detector response. The Millennium Chromatography Manager System (Waters)
was used in this evaluation.
3.1.4 Glass vials, 2-mL, with poly(tetrafluoroethylene)-lined caps for
desorbing samples.
3.1.5 A dispenser capable of delivering 1.0 mL of desorbing solvent.
3.2 Reagents
3.2.1 Tetraethyltin. Tetraethyltin, technical grade, was obtained from
Chem Services.
3.2.2 Carbon disulfide. Carbon disulfide, Omni Solv grade, was obtained
from E. M. Science.
3.2.3 p-Cymene. p-Cymene, 99%, was obtained from Aldrich Chemical.
3.2.4 Desorbing solvent. Add 8 µL of p-cymene to 1 L of carbon disulfide.
3.3 Standard preparation
3.3.1 Prepare stock standards of tetraethyltin in the desorbing solvent.
Eight microliters of tetraethyltin diluted to 10 mL with the desorbing
solvent will give a stock standard of 950 µg/mL.
3.3.2 Prepare analytical standards by diluting the stock standards with
the desorbing solvent. A 9.5 µg/mL standard solution corresponds to the
target concentration.
3.4 Sample preparation
3.4.1 Transfer the sorbent of the front and the back section to separate
glass vials.
3.4.2 Add 1.0 mL of the desorbing solvent to each vial.
3.4.3 Cap the vials and shake them on a mechanical shaker for 30 min.
3.5 Analysis
3.5.1 GC conditions
| column: |
RTx-1 (60 m x 0.32-mm i.d., 1.0-µm df) |
| oven temperature: |
160°C |
| injector temperature: |
250°C |
| detector temperature: |
300°C |
| injection size: |
1.0 µL |
| retention time: |
p-cymene | 6.05 min |
|
tetraethyltin | 6.48 min |
| hydrogen: |
27 mL/min |
| air: |
415 mL/min |
| make-up gas (N2): |
29 mL/min |
| split ratio: |
39.1 |
|
|
3.5.2 An internal standard calibration method is used. A calibration
curve can be constructed by plotting concentration of the analyte versus
ISTD-corrected response of standard injections. Bracket the samples with
freshly prepared standards.
Figure 3.5.1. Chromatogram of tetraethyltin standard at the target
concentration. 1 = p-cymene, 2 = tetraethyltin
Figure 3.5.2. Calibration curve of tetraethyltin made from the data of Table 4.5.
3.6 Interferences (analytical)
3.6.1 Any compound that responds to FID and has a similar retention time
as the analyte or the internal standard is a potential interference. If
any potential interferences are reported, they should be considered
before samples are desorbed. Generally, chromatographic conditions can be
altered to separate an interference from the analyte.
3.6.3 When necessary, the identity or the purity of an analyte peak may be
confirmed with additional analytical data (Section 4.11).
3.7 Calculations
The amount (in micrograms) of tetraethyltin per milliliter is obtained
from the appropriate calibration curve. This amount is corrected by
subtracting the amount (if any) found in the blank. The air concentration
is calculated using the following formula.
| mg/m3 = |
(micrograms per mL) × (extraction volume, mL) (liters of air sampled) × (extraction efficiency) |
| Where: | Desorption volume = 1 mL |
| Desorption efficiency = 1.026 |
To compare the concentration to the OSHA PEL for tin in organic compounds
(0.1 mg/m3), apply a conversion factor of 0.5052 to find the tin content.
3.8 Safety precautions (analytical)
3.8.1 Follow the rules set down in your Chemical Hygiene Plan.
3.8.2 Avoid skin contact and inhalation of all chemicals.
3.8.3 Wear safety glasses and a lab coat at all times while in the
lab area.
4. Backup Data
4.1 Determination of detection limits
Detection limits (DL), in general, are defined as the amount (or
concentration) of analyte that gives a response (YDL) that is
significantly different (three standard deviations (SDBR)
from the background response (YBR).
YDL - YBR = 3(SDBR)
The direct measurement of YBR and SDBR in
chromatographic methods is
typically inconvenient and difficult because YBR is usually extremely
low. Estimates of these parameters can be made with data obtained from
the analysis of a series of analytical standards or samples whose
responses are in the vicinity of the background response. The regression
curve obtained for a plot of instrument response versus concentration of
analyte will usually be linear. Assuming SDBR and the
precision of data
about the curve are similar, the standard error of estimate (SEE) for the
regression curve can be substituted for SDBR in the above equation. The
following calculations derive a formula for DL:
| Yobs | = observed response |
| Yest | = estimated response from regression curve |
| n | = total no. of data points |
| k | = 2 for a linear regression curve |
At point YDL on the regression curve
| YDL = A(DL) + YBR | A = analytical sensitivity
(slope) |
therefore
Substituting 3(SEE) + YBR for YDL gives
4.2 Detection limit of the analytical procedure (DLAP)
The DLAP is measured as the mass of analyte actually introduced into the
chromatographic column. Ten analytical standards of tetraethyltin whose
concentrations was equally spaced from 0 to 0.950 µg/mL were prepared.
The standard containing 0.950 µg/mL represented approximately 10 times
the baseline noise. These solutions were analyzed with the recommended
analytical parameters (1 µL injection, 39.1 split ratio). The data
obtained were used to determine the required parameters (A and SEE)
for the calculation of the DLAP. Values of 0.00289 and 0.00461 were
obtained for A and SEE respectively. DLAP was calculated to be 4.8 pg.
Table 4.2
Detection Limit of the Analytical Procedure for tetraethyltin
|
| concentration | mass on column | response |
| (µg/mL) | (pg) | |
|
| 0.000 | 0.0 | 0.005117 |
| 0.095 | 2.4 | 0.006042 |
| 0.190 | 4.9 | 0.019923 |
| 0.285 | 7.3 | 0.020949 |
| 0.380 | 9.7 | 0.030539 |
| 0.475 | 12.1 | 0.029186 |
| 0.570 | 14.6 | 0.051692 |
| 0.665 | 17.0 | 0.053757 |
| 0.760 | 19.4 | 0.056698 |
| 0.855 | 21.9 | 0.069562 |
| 0.950 | 24.3 | 0.069456 |
|
Figure 4.2. Plot of data to determine DLAP.
4.3 Detection limit of the overall procedure (DLOP)
The DLOP is measured as mass per sample and expressed as equivalent air
concentration, based on the recommended sampling parameters. Ten
samplers were spiked with tetraethyltin ranging from 0 to 0.950 µg.
The latter amount, when spiked on a sampler, would produce a peak
approximately 10 times the baseline noise for a sample blank. These
samples were analyzed with the recommended analytical parameters, and
the data obtained used to calculate the required parameters (A and SEE)
for the calculation of the DLOP. Values of 0.0800 and 0.00549 were
obtained for A and SEE respectively. DLOP was calculated to be 0.21
µg/sample (4.3 µg/m3).
Table 4.3
Detection Limit of the Overall Procedure for Tetraethyltin
|
| mass per sample | response |
| (µg) | |
|
| 0.000 | 0.002780 |
| 0.095 | 0.003864 |
| 0.190 | 0.020702 |
| 0.285 | 0.022380 |
| 0.380 | 0.032509 |
| 0.475 | 0.035886 |
| 0.570 | 0.056129 |
| 0.665 | 0.059509 |
| 0.760 | 0.057776 |
| 0.855 | 0.061797 |
| 0.950 | 0.081816 |
|
Figure 4.3. Plot of data to determine the DLOP and RQL.
4.4 Reliable quantitation limit
The RQL is considered the lower limit for precise quantitative
measurements. It is determined from the regression line data obtained
for the calculation of the DLOP (Section 4.3) providing at least 75% of
the analyte is recovered. The RQL is defined as the amount of analyte
that gives a response (YRQL) such that
YRQL - YBR = 10(SDBR)
therefore
RQL = 0.69 µg per sample (14.4 µg/m3)
Figure 4.4. Chromatogram of tetraethyltin RQL. 1 = p-cymene, 2 = tetraethyltin.
Recovery at this level is 106.2%.
4.5 Precision (analytical method)
The precision of the analytical procedure is defined as the pooled
relative standard deviation (RSDP). Relative standard deviations were
determined from six replicate injections of analytical standards at 0.5,
0.75, 1, 1.5, and 2 times the target concentration. After assuring that
the RSDs satisfy the Cochran test for homogeneity at the 95% confidence
level, RSDP was calculated.
Table4.5 Instrument Response to Tetraethyltin
|
| x target concn | 0.5 x | 0.75 x | 1 x | 1.5 x | 2 x |
| µg/mL | 4.75 | 7.12 | 9.50 | 14.24 | 18.99 |
|
| Response | 0.298908 | 0.470980 | 0.603011 | 0.896033 | 1.205802 |
| 0.299132 | 0.465653 | 0.603646 | 0.896054 | 1.214870 |
| 0.293568 | 0.464225 | 0.598385 | 0.896632 | 1.208242 |
| 0.297834 | 0.470271 | 0.582012 | 0.908579 | 1.207354 |
| 0.308123 | 0.466955 | 0.590737 | 0.916217 | 1.213500 |
| 0.302405 | 0.471602 | 0.600238 | 0.895729 | 1.209036 |
 | 0.299995 | 0.468281 | 0.596338 | 0.901541 | 1.209801 |
| SD | 0.004894 | 0.003079 | 0.008414 | 0.008755 | 0.003588 |
| RSD % | 1.63 | 0.66 | 1.41 | 0.97 | 0.30 |
|
The Cochran test for homogeneity requires the calculation of the g
statistics according to the following formula:
The critical value of the g statistic, at the 95% confidence level, for
five variances, each associated with six observations, is 0.5065.
Because the g statistic obtained (0.4347) does not exceed this value, the
RSDs within each level can be considered equal and they can be pooled
(RSDP) to give an estimated RSD for the concentration range studied.
= 1.11%
4.6 Precision (overall procedure)
The precision of the overall procedure is determined from the storage
data in Section 4.7. The determination of the standard error of estimate
(SEER) for a regression line plotted through the graphed storage data
allows the inclusion of storage time as one of the factors affecting
overall precision. The SEER is similar to the standard deviation,
except it is a measure of dispersion of data about a regression line
instead of about a mean. It is determined with the following equation:
| n | = total no. of data points |
| k | = 2 for linear regression |
| k | = 3 for quadratic regression |
| Yobs | = observed % recovery at a given time |
| Yest | = estimated % recovery from the regression line at the same given time |
An additional 5% for pump error (SP) is added to the SEER by
the addition of variances to obtain the total standard error of estimate.
The precision at the 95% confidence level is obtained by multiplying the
standard error of estimate (with pump error included) by 1.96 (the
z-statistic from the standard normal distribution at the 95% confidence
level). The 95% confidence intervals are drawn about their respective
regression lines in the storage graphs, as shown in Figures 4.7.1 and
4.7.2. The precision of the overall procedure is ±12.0%.
4.7 Storage test
Storage samples were prepared by drawing samples from a controlled
test atmosphere (80% relative humidity and 22°C) at 0.2 L/min
for 120 min. The concentration of tetraethyltin was at two times the
target concentration. Thirty-six samples were prepared. Six samples were
analyzed on the day of preparation. One-half of the remaining samples
were stored in a refrigerator (5°C) and the other half were
stored at ambient temperature (about 22°C) in a closed drawer.
At 2-4 day intervals, three samples were selected from each of the
two storage sets and analyzed.
Table 4.7 Storage Test for Tetraethyltin
|
| time | | percent recovery | | | percent recovery | |
| (days) | | (ambient) | | | (refrigerated) | |
|
| 0 | 98.2 | 99.2 | 103.1 | 98.2 | 99.2 | 103.1 |
| 0 | 97.6 | 100.8 | 101.1 | 97.6 | 100.8 | 101.1 |
| 2 | 98.1 | 97.2 | 92.6 | 93.9 | 94.5 | 95.8 |
| 6 | 91.6 | 89.9 | 87.9 | 90.2 | 89.1 | 87.7 |
| 9 | 89.4 | 91.4 | 89.4 | 92.1 | 87.6 | 87.2 |
| 12 | 95.5 | 83.7 | 93.6 | 88.7 | 91.9 | 89.5 |
| 15 | 90.8 | 91.0 | 89.6 | 86.1 | 83.5 | 86.9 |
|
Figure 4.7.1. Ambient storage test for tetraethyltin.
Figure 4.7.2. Refrigerated storage test for tetraethyltin.
4.8 Reproducibility
Reproducibility samples were prepared by collecting them from a controlled
test atmosphere similar to that used in the storage test. The samples
were submitted to an SLTC Service Branch for analysis. The samples were
analyzed after being stored for 2 days at 5°C. No sample result
had a deviation greater than the precision of the overall procedure
determined in Section 4.7.
Table 4.8 Reproducibility Data for Tetraethyltin
|
| µg expected | µg found | percent found | percent deviation |
|
| 9.73 | 9.86 | 101.3 | +1.3 |
| 9.95 | 10.45 | 105.0 | +5.0 |
| 9.81 | 10.21 | 104.1 | +4.1 |
| 9.89 | 10.19 | 103.0 | +3.0 |
| 9.94 | 10.17 | 102.3 | +2.3 |
| 9.91 | 10.19 | 102.8 | +2.8 |
|
4.9 Sampler capacity
The sampling capacity of the front section of an XAD-7 tube was tested by
sampling from a dynamically generated test atmosphere of tetraethyltin
(0.4 mg/m3). The samples were collected at 0.2 L/min and the relative
humidity was 80% at 22°C. A complete XAD-7 sampling tube was
placed in-line behind the 100-mg test section and changed at regular
intervals. The 5% breakthrough point was not observed in 8 hours of sampling.
Table 4.9
Breakthrough of Tetraethyltin with XAD-7 Sampling Tubes
| |
|
| sampling | air | downstream | breakthrough | downstream | breakthrough |
| time (min) | volume (L) | concn (mg/m3) | (%) | concn (mg/m3) | (%) |
|
| 30 | 6 | 0 | 0 | 0 | 0 |
| 90 | 18 | 0 | 0 | 0 | 0 |
| 150 | 30 | 0 | 0 | 0 | 0 |
| 210 | 42 | 0 | 0 | 0 | 0 |
| 270 | 54 | 0 | 0 | 0 | 0 |
| 330 | 66 | 0 | 0 | 0 | 0 |
| 390 | 78 | 0 | 0 | 0 | 0 |
| 450 | 90 | 0 | 0 | 0 | 0 |
|
4.10 Desorption efficiency and stability of desorbed samples
4.10.1 Desorption efficiency
The desorption efficiencies (DE) of tetraethyltin were determined by
liquid-spiking 100-mg portions of XAD-7 with the analyte at 0.05 to 2
times the target concentration. These samples were stored overnight at
ambient temperature and then desorbed and analyzed. The average
desorption efficiency over the working range of 0.5 to 2 times the
target concentration was 102.6%.
Table 4.10.1 Desorption Efficiency of Tetraethyltin
|
| x target concn | 0.05 x | 0.1 x | 0.2 x | 0.5 x | 1.0 x | 2.0 x |
| (µg/sample) | 0.48 | 0.95 | 1.90 | 4.75 | 9.50 | 18.99 |
|
| DE(%) | 72.1 | 105.2 | 95.5 | 101.0 | 101.1 | 101.9 |
| 109.6 | 105.8 | 101.9 | 103.8 | 101.5 | 102.0 |
| 92.9 | 96.9 | 100.5 | 102.0 | 102.7 | 103.1 |
| 107.5 | 106.0 | 99.9 | 106.3 | 102.9 | 99.6 |
| 137.1 | 110.8 | 101.1 | 105.0 | 102.5 | 104.6 |
| 82.5 | 99.4 | 102.1 | 101.3 | 104.4 | 102.1 |
| Average | 100.3 | 104.0 | 100.2 | 103.2 | 102.5 | 102.2 |
|
4.10.2 Stability of desorbed samples
The stability of the desorbed samples was investigated by re-analyzing
the target concentration samples 24 h after initial analysis. After
the original analysis was performed, three vials were recapped with
new septa while the remaining three retained their punctured septa.
The samples were re-analyzed with fresh standards.
Table 4.10.2 Stability of Desorbed Samples of Tetraethyltin
|
| punctured septa replaced | | | | punctured septa retained |
|
| initial | DE after | | initial | DE after | |
| DE (%) | one day (%) | difference | DE (%) | one day (%) | difference |
|
| 101.9 | 100.3 | -1.6 | 99.6 | 100.0 | +0.4 |
| 102.0 | 100.3 | -1.7 | 104.6 | 102.3 | -2.3 |
| 103.1 | 100.6 | -2.5 | 102.1 | 102.0 | -0.1 |
| average | | | average | |
| 102.3 | 100.4 | -1.9 | 102.1 | 101.4 | -0.7 |
|
4.11 Qualitative analysis
Tetraethyltin may be confirmed by GC/MS using the GC conditions similar to those in Section 3.5.1.
Figure 4.11. Mass spectrum of tetraethyltin.
5. References
5.1. Air Contaminants -- Permissible Exposure Limits, Title 29, Code of
Federal Regulations, Part 1910.1000.
5.2. Criteria for a recommended standard ... Occupational exposure to
organotin compounds, U.S. Department of Health, Education, and Welfare,
Public Health Service, Center for Disease Control, National Institute
for Occupational Safety and Health, November 1976. DHEW (NIOSH)
Publication No. 77-115.
5.3. NIOSH Manual of Analytical Methods, 4th ed., Method No. 5504, 1994.
|