NAME: Vydate
SYNONYM(s):
2-(Dimethylamino)-N-[[(methylamino)carbonyl]oxy]-2-oxoethanoimido-
thioic acid methyl ester; Oxamyl; Thioxamyl
IMIS: 2585
CAS: 23135-22-0
NIOSH: RTECS RP2300000; 53650
DESCRIPTION:
Crystalline solid, slight sulfurous odor.
MP:
100-102 C
Exposure Limits
Health Factors
HEALTH EFFECTS:
LD50 (oral, rat) 5 mg/kg
Monitoring
PRIMARY SAMPLING/ANALYTICAL METHOD (SLC1):
MEDIA:
OSHA Versatile Sampler (OVS-2) - 13 mm XAD-2 tube (270/140 mg sections, 20/60 mesh) with Glass Fiber Filter enclosed.
MAX V:
60 Liters MAX F:
1.0 L/min
ANL 1:
High Performance Liquid Chromatography; HPLC
REF:
2 (OSHA In-House File)
CLASS:
Partially Validated
NOTE:
OSHA personnel may obtain sampling tubes from SLTC.
COND:
Acetonitrile extraction; Zorbax ODS column; 45% Acetonitrile
55% water; 1 mL/min; UV 214; Retention time 2.6 min;
DL 0.2 ug/sample; C/P JML 10/83
BULK METHOD:
Limit the amount of bulk submitted to one gram or one mL.
|