OSHA IMIS Code Number: 1267
Chemical Abstracts Service (CAS) Registry Number: 12604-58-9
Other Chemical Abstracts Service (CAS) Registry Numbers: 11147-86-7
NIOSH Registry of Toxic Effects of Chemical Substances (RTECS) Identification Number: LK2900000
Chemical Description and Physical Properties:
dark, odorless solid particles
vapor pressure: approx. 0 mm
Incompatibilities: Strong oxidizers
OSHA Permissible Exposure Limit (PEL):
General Industry: 1 mg/m3
Construction Industry: 1 mg/m3 TWA
American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV): 1 mg/m3 TWA; 3 mg/m3 STEL
National Institute for Occupational Safety and Health (NIOSH) Recommended Exposure Limit (REL): 1 mg/m3 TWA; 3 mg/m3 STEL
Potential Symptoms: Eye, respiratory system irritation; In animals: bronchitis, pneumonitis
Health Effects: Irritation-Eye, Nose, Throat, Skin---Mild (HE16)
Affected Organs: Respiratory system, eyes
Primary Laboratory Sampling/Analytical Method (SLC1):
- sampling media: Mixed Cellulose Ester Filter (MCEF) 0.8 microns
maximum volume: 960 Liters
minimum volume: 480 Liters
maximum flow rate: 2.0 L/min (TWA)
maximum volume: 30 Liters
maximum flow rate: 2.0 L/min (STEL)
current analytical method: Atomic Absorption Spectroscopy; AAS
method reference: 2 (OSHA ID-121)
sampling analytical error: 0.19
method classification: Fully Validated
alternate analytical method: Inductively Coupled Argon Plasma; ICP/AES
method reference: 2 (OSHA ID-125G)
sampling analytical error: 0.12
method classification: Fully Validated
note: If the filter is not overloaded, samples may be collected up to + an 8-hour period. Analytical method does not distinguish between dust and fume. When analysis of a compound is requested, an elemental analysis is performed and reported as the compound.