Example Controls Required for Laser Classes from ANSI Z-136.1 (1988)

                                                                 y = yes      s = sometimes       --  = no

 
Control Measures Class
I IIA II IIIA IIIB IV
Protective Housing y y y y y y
Interlocks on Protective Housing -- -- -- y y y
Limited Open Beam Path -- -- -- -- y y
Beam Stop or Attenuator -- -- -- s s y
Activation Warning System -- -- -- -- s y
Labels -- y y y y y
Area Posting -- -- s s y y
Standard Operating Procedures -- -- -- -- s y
Output Emission Limitations -- -- -- LSO Determines
Education and Training -- -- -- y y y
Authorized Personnel -- -- -- -- y y
Alignment Procedures -- -- y y y y
Eye Protection -- -- -- -- s y
Spector Control -- -- -- -- s y
 
 