![]() Design Criteria Casting Hood: Q = 500 scfm/sq ft of equipment + 100 scfm/sq openings hc = .5 VPduct Vtransport ≥ 400 fpm Cooling Hood: Q = 100 scfm/sq ft openings + 500 scfm per gal H20 used per minute hc = 3.3 VP Vduct ≥ 2000 fpm For problems with accessibility in using figures and illustrations in this document, please contact the Directorate of Technical Support and Emergency Management at (202) 693-2300. |