Inspection Detail
Inspection: 122311996 - Fox Valley Systems, Inc.
Inspection Information - Office: Naperville Area Office
Site Address:
Fox Valley Systems, Inc.
640 Industrial Drive
Cary, IL 60013
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3993
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 11/30/1995
Emphasis:
Case Closed: 08/06/1996
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361864937 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 7 | ||||
Current Violations | 7 | 7 | ||||
Initial Penalty | $10,500 | $0 | $0 | $0 | $0 | $10,500 |
Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 12/15/1995 | 05/01/1996 | $1,000 | $1,400 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100106 E02 IVD | 12/15/1995 | 01/17/1996 | $1,000 | $1,400 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100106 E02 IVC | 12/15/1995 | 01/17/1996 | $1,000 | $1,400 | $0 | I - Informal Settlement | ||
4. | 01004 | Serious | 19100106 E02 III | 12/15/1995 | 01/17/1996 | $1,000 | $1,400 | $0 | I - Informal Settlement | ||
5. | 01005A | Serious | 19100119 D | 12/15/1995 | 01/17/1996 | $1,000 | $1,750 | $0 | I - Informal Settlement | ||
6. | 01005B | Serious | 19100119 E01 | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
7. | 01005C | Serious | 19100119 F01 | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
8. | 01005D | Serious | 19100119 G01 I | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
9. | 01005E | Serious | 19100119 J02 | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
10. | 01005F | Serious | 19100119 J04 I | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
11. | 01005G | Serious | 19100119 N | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
12. | 01006 | Serious | 19100147 C01 | 12/15/1995 | 01/17/1996 | $1,000 | $1,750 | $0 | I - Informal Settlement | ||
13. | 01007A | Serious | 19101200 F05 I | 12/15/1995 | 01/17/1996 | $1,000 | $1,400 | $0 | I - Informal Settlement | ||
14. | 01007B | Serious | 19101200 F05 II | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement | ||
15. | 01007C | Serious | 19101200 H | 12/15/1995 | 01/17/1996 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Employees #2 and #3 were cleaning a spray paint can filling line. They were flushing the paint line with toluene and running the waste solvent into a 5-gallon open plastic pail. The solvent splashed into the pail and generated considerable spray. Apparently, the splashing solvent generated a static charge, produced a spark, and ignited the solvent vapors. Employee #3, who was leaning over the pail, and Employee #2, who was holding the hose used to fill the pail, were burned and hospitalized. Employee #1 was exposed to carbon monoxide while trying to fight the fire.
Keywords: BURN, STATIC ELECTRICITY, FLAMMABLE LIQUID, WORK RULES, CLEANING, FIRE, TOLUENE, SPARK, ARM, CARBON MONOXIDE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 122311996 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 122311996 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
3 | 122311996 | Non Hospitalized injury | Other | Occupation not reported |