February 10, 2005

Mr. Brad Schiegg
Electrical Engineering Manager
Optima Machinery Corporation
1330 Contract Drive
Green Bay, WI 54304

Dear Mr. Schiegg:

This is in response to your January 17, 2005 letter to the Occupational Safety and Health Administration (OSHA) requesting a formal interpretation regarding OSHA compliance for a packaging machine, which is designed in accordance with the national consensus standards for this equipment (e.g., ANSI/PMMI B155.1-2000).

Your letter seeks OSHA's acceptance of your procedures, listed below, in terms of the design/risk assessment of this machine:

  1. 29 CFR 1910.147: Control of hazardous energy (lockout/tagout);
  2. 29 CFR Part 1910: Subpart O, Machine and machine guarding;
  3. ANSI/ASSE Z244.1-2003: Control of Hazardous Energy Lockout/Tagout and Alternative Methods.

In regard to your enclosed design and risk assessment information, our office has not performed a detailed review, nor approved the adequacy of such design in meeting the above referenced OSHA, ANSI, or any other consensus standards. OSHA does not test, approve, certify, or endorse any equipment, product, or procedure, including machine design and risk assessment techniques.

Should you wish to research OSHA policy regarding your referenced topics, you may elect to consult OSHA's website at
http://www.osha.gov. For example, enforcement policy for the Control of Hazardous Energy Lockout/Tagout and Alternative Methods consensus standard may be found in the November 10, 2004 letter to the Chairman of the Z244 American National Standards Committee. Specifically, OSHA has not determined that, in all cases, compliance with specific provisions of the ANSI Z244.1-2003 Standard and its annexes would constitute compliance with the relevant OSHA standards.1 Please refer to our website interpretation section for additional detail on this and other hazardous energy control (e.g., §1910.147) policy.

Thank you for your interest in occupational safety and health. We hope you find this information helpful. OSHA requirements are set by statute, standards, and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. If you have any further questions, please feel free to contact the Office of General Industry Enforcement at (202) 693-1850.

Sincerely,


Richard E. Fairfax, Director
Directorate of Enforcement Programs


1 The OSH Act contemplates a distinction between the national consensus standard process and the process of OSHA rulemaking. While the former often produces information useful in the latter, it is not equivalent. Section 5(a)(2) of the OSH Act requires employers to comply with OSHA standards (29 USC §654(a)(2)). [ back to text ]


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close