OSHA requirements are set by statute, standards, and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at http://www.osha.gov.


November 10, 9999

MEMORANDUM FOR: REGIONAL ADMINISTRATORS

FROM: RICHARD E. FAIRFAX, DIRECTOR
DIRECTORATE OF COMPLIANCE PROGRAMS

SUBJECT: OSHA policy regarding PEL adjustments for extended work shifts.


The purpose of this memorandum is to resolve issues concerning adjustments of the PEL during extended work shifts. This applies for exposures to the noise levels of Table G-16 of 29 CFR 1910.95 or substances found in Subpart Z. Current OSHA policy requires only the action level to be reduced for exposures to noise during extended work shifts; the PEL is not required to be adjusted. The only standards which require PEL adjustments are the lead standards in construction and general industry. These standards have a specific provision which requires work shift adjustments. Existing policy for Occupational Exposure to Cotton Dust also has a requirement to adjust extended work shifts when employees are required to wear respirators for a portion of the work shift to reduce their level of exposure, as set forth in the Federal Register, Vol. 45, No. 251, pp. 85736-85739. The contribution that the extended work hours adds to employee exposure must be included in calculating the required time respirators must be worn during the shift.

As stated in a previous memorandum dated November 8, 1996:
Compliance officers can choose one of two approaches for employees who work extended work shifts beyond 8 hours. The choice taken will depend on the nature of the hazardous chemical.

  1. The first approach is to sample what the compliance officer believes to be the worst continuous 8-hour work period of the entire extended work shift.

  2. The second approach is to collect multiple samples over the entire work shift. Sampling is done such that multiple personal samples are collected during the first 8-hour work period and additional samples are collected for the extended work shift. Unless a compliance officer is dealing with lead, the PEL in this approach is calculated based upon the worst 8 hours of exposure during the entire work shift.
We hope you find this clarification helpful. If you have any questions or if we can be of any further assistance, please contact the [Office of Health Enforcement] at (202) 693-2190.

[Corrected 06/21/2007]


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.