December 21, 1998

Mr. David L. Thorpe
Manufacturing Engineer
General Motors
Metal Fabricating Division Headquarters
5607 New King Street
Troy, Michigan 48098

Dear Mr. Thorpe:

This is in response to your letter of September 8, addressed to Mr. John B. Miles, Jr., Former Director of Compliance Programs. Your letter was to confirm your representative's conversation with Ms. Alcmene Haloftis of my staff concerning the use of slide locks (mechanical safety devices) in lieu of die blocks on mechanical power presses, as required by the Occupational Safety and Health Administration's (OSHA's) standard, 29 CFR 1910.217(d)(9)(iv). We apologize for the delay in responding to your letter.

First, this response is to correct the apparent misunderstanding of the communication between your representative and my staff member, Ms. Haloftis. It is apparent that you are under the perception that slide locks meet the intent of the referenced standard. The slide locks, however, are clearly susceptible to failure caused by the misalignment of the gear or the supporting pin; unlike the die block which has no mechanical components subject to failure.

Further, it should be noted, that the American National Safety Institute (ANSI) standard, ANSI B11.1-1998, does not recommend slide locks or devices which have components susceptible to failure.

Therefore, as Mrs. Haloftis recommended in the original telephone communication, this situation would be properly assessed through a variance application. The variance application would be addressing a specific use for a specific piece of equipment, under specific conditions. That is, a variance application would assess and determine the potential hazards of this type of safeguard specific to a particular power press, and would not determine blanket exception of all slide locks on all power presses which it seems that you intend to secure from OSHA. You may request to apply for a variance application from the Office of Technical Support by contacting Mr. Steve Witt, Director, at 202-693-2300.

Thank you for your inquiry. If you have questions regarding the preceding, please contact Ms. Alcmene Haloftis of my staff at 202-693-1850.

Sincerely,

Richard E. Fairfax, Director
Directorate of Compliance Programs



Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close