• Standard Number: 1926.106; 1926.502

March 21, 1997

Mr. Sante Camo
Project Manager
Weidlinger Associates, Inc.
Consulting Engineers
333 Seventh Avenue
New York, New York 10001

Dear Mr. Camo:

This is in response to your letter of February 12, concerning the use of a fall protection enclosure in lieu of personal fall arrest systems, and the need for a rescue skiff when employees are working over or adjacent to water.

The use of a fully enclosed structural work platform would appear to prevent employees from falling off the work platform and into the water provided the requirements of 29 CFR 1926.502 are met with regard to the guardrails. Such an enclosure would be acceptable in lieu of the use of personal fall arrest systems (i.e. body harnesses). However, it is not clear from the drawings submitted how an employee would be protected from falling or sliding down and out the end of the enclosure, and then down to the water. Some means of protection would be necessary across the downside end of the enclosure before the intent of the requirement is fully met.

The intent of paragraph 1926.106(d) is to ensure prompt rescue of employees that fall into the water. Where an employee is working over or adjacent to water, regardless of other precautions that are taken to prevent employees from falling, OSHA requires that employers supply the appropriate means necessary, such as a skiff, to effect a prompt water rescue. I am enclosing a copy of a letter of interpretation which spells out the Agency's criteria for determining when a lifesaving skiff is considered to be "immediately available".

If you have any further questions, please contact: The Office of Construction Standards and Compliance Assistance, U.S. Department of Labor - OSHA, 200 Constitution Avenue, N.W., Room N3621, Washington, D.C. 20210.

Sincerely,

Roy F. Gurnham, Manager
Office of Construction Standards
and Compliance Assistance


Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.