Powered by Google logoTranslate
Standard Interpretations - (Archived) Table of Contents
• Standard Number: 1910.151; 1910.1200
• Status: Archived

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

August 22, 1996

Mr. Timothy J. Batz, CSP, ARM Senior Vice President Loss Control Manager Lockton Companies Post Office Box 221300 Denver, Colorado 80222-9300

Dear Mr. Batz:

This is in response to your letter of July 31, to the Office of General Industry Compliance Assistance, requesting clarification regarding the use of eyewash stations as required by 1910.151.

You ask in your letter what is a considered a corrosive material, and is there a certain ph-level that quantifies this. Secondly, you ask what travel distance can an eyewash station not exceed from the exposed worker, and asked for clarification of the Occupational Safety and Health Administration's (OSHA) meaning of "within the work area."

OSHA's definition of a corrosive is a chemical that causes visible destruction of, or irreversible alterations in, living tissue by chemical action at the site of contact. Under the provisions of OSHA's hazard communication standard, (29 CFR 1910.1200(g)), employers are required to have a material safety data sheet (MSDS) in the work place for each hazardous chemical which they use. The MSDS provides information you need to ensure proper protective measures are implemented prior to exposure, including emergency and first aid procedures.

Regarding your inquiry as to the required proximity of the eye/face wash units and emergency deluge showers, 29 CFR 1910.151(c) requires that these units, "...shall be provided within the work area for immediate emergency use." OSHA standards are silent on a required distance and therefore the Agency refers to the recommendations with respect to highly corrosive chemicals contained in American Standard for Emergency Eyewash and Shower Equipment ANSI Z358.1-1990. OSHA interprets the phrase "within the work area" to require that eye/face wash units and emergency deluge showers both be located within 10 feet of unimpeded travel distance from the corrosive material hazard or, in the alternative, within the distance recommended by a physician or appropriate official the employer consulted.

Since your questions were asked in the context of an automobile service garage, enclosed is a copy of OSHA Instruction STD 1-8.2, which provides guidelines regarding eyewash and body flushing facilities required for immediate emergency use in electric storage battery charging and maintenance areas.

We hope this information is responsive to your concerns. If you have any further questions, please contact Renee Carter of my staff at (202) 219-8041, x117.

Sincerely,

Raymond E. Donnelly, Director Office of General Industry Compliance Assistance

Enclosure

July 31,1996

General Industry Compliance Administrator U.S. Department of Labor Occupational Safety & Health Administration 200 Constitution Avenue, N.W., Room N-3107 Washington, D.C. 20210

Dear Sir:

I am seeking clarification regarding the use of eyewash stations as required by 1910.151.

The Standard requires that where the eyes or body of any person may be exposed to injurious, corrosive materials suitable facilities for quick drenching or flushing of the eyes or body shall be provided within the work area for immediate emergency use.

My first questions is "What is considered a corrosive material?" Is there a certain pH-level that quantifies this?

The second questions has to do with what constitutes "within the work area?" In other words, what travel distance can the eyewash station not exceed from the exposed worker?

I ask these questions in the context of an automobile service garage. Your prompt response will be greatly appreciated.

Sincerely,

LOCKTON COMPANIES

Timothy J. Batz, CSP, ARM Senior Vice President Loss Control Manager
Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close