• Standard Number: 1926.500; 1926.451(g); 1926.451(h)

September 25, 1995

Mr. Carl Heinlein
Associate Director
The Associated General
Contractors of America
1957 E. Street, N.W.
Washington, D.C. 20006

Dear Mr. Heinlein:

This is in response to your letter requesting an interpretation of the Occupational Safety and Health Administration's (OSHA) New Fall Protection Standard for the Construction Industry (1926.500).

With regard to the applicability of the new fall protection regulations (Part 1926, Subpart M) to traditional one-sided masonry scaffolds, please be advised that, in accordance with 1926.500(2)(i) and .500(3)(i), the requirement for fall protection and the criteria for guardrails contained in Subpart M do not apply to employees working from scaffolds. This activity is addressed in Subpart L. Therefore, according to 1926.451[(g) and (h)], fall protection is required for employees working on masonry scaffolds (including overhand bricklaying when performed from a scaffold) whenever the fall height is greater than 10 feet.

With regard to the open side of masonry scaffolds, a guardrail is not required on the side where work is being performed provided the open side edge of the scaffold is within 14 inches of the wall.

If you have any questions, please call me or Dale Cavanaugh of my staff at (202)219-8136.


Roy F. Gurnham, P.E., J.D.
Office of Construction and Maritime
Compliance Assistance

Standard Interpretations - Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.