NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

August 5, 1994

Mr. M. L. Hall
Safety/Emergency Response
Program Manager
IBM Mail Drop 3600
Somers, N.Y. 10589

Dear Mr. Hall:

This is in response to your telefaxed memorandum of July 6 to Mr. Ronald J. Davies of my staff requesting clarification of 29 CFR 1910.147 - Control of Hazardous Energy Standard. Specifically, you requested confirmation that the individual performing a periodic inspection required by 1910.147(c)(6) must be an authorized employee.

Pursuant to 1910.147(c)(6)(i)(A), a periodic inspection must be performed by an authorized employee other than the one(s) utilizing the energy control procedure being inspected. For the purpose of complying with the intent of this standard, authorized employee means a qualified person whom the authority and responsibility to perform a specific lockout or tagout inspection has been given by the employer. A qualified person is a person who has been trained and has demonstrated proficiency, in compliance with 1910.147(c)(7), to perform servicing and maintenance on the machine or equipment to be inspected. In your memorandum you described three periodic inspection scenarios. The individuals in these scenarios must be authorized employees, as noted above.

Periodic inspection by an authorized employee is intended to assure that the energy control procedure continues to be implemented properly and that the employees involved are familiar with their responsibilities under that procedure. The inspection must be able to determine three things: first, whether the steps in the energy control procedure are being followed; second, whether the employees involved know their responsibilities under the procedure; and third, whether the procedure is adequate to provide the necessary protection, and what changes, if any, are needed. The Final Rule, a copy of which is enclosed for your use, provides some additional guidance as to the inspector's duties in performing a periodic inspection, to assure that necessary information about the energy control procedure and its effectiveness is obtained. The preamble discussions of the definition of an authorized employee, page 36665, and on the periodic inspections, page 36673, were referenced for the preceding clarifications.

We appreciate your interest in employee safety and health. If we can be of further assistance, please contact [the Office of General Industry Compliance Assistance at (202) 693-1850].

Sincerely,

John B. Miles, Jr., Director
Directorate of Compliance Programs


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.