Powered by Google logoTranslate
Standard Interpretations - (Archived) Table of Contents
• Standard Number: 1910.1030
• Status: Archived

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

July 28, 1992

Mr. James C. Cokendolpher
Texas Tech University
Health Sciences Center
Department of Preventive Medicine
NPTN-Antimicrobial Compliant System
Lubbock, Texas 79430

Dear Mr. Cokendolpher:

This is in response to your letter of April 22, in which you requested clarification concerning the use of appropriate disinfectants as required by the Occupational Safety and Health Administration (OSHA) regulation 29 CFR 1910.1030, "Occupational Exposure to Bloodborne Pathogens". Your question specifically relates to the use of sodium hypochlorite solutions (bleach) for disinfection of environmental surfaces. We apologize for the delay in this response.

You correctly note in your letter that OSHA Instruction CPL 2- 2.44C, "Enforcement Procedures for the Occupational Exposure to Bloodborne Pathogens Standard", states that disinfectant products registered by the U.S. Environmental Protection Agency (EPA) as tuberculocidal are considered "appropriate" for the cleanup of a contaminated item or surface. OSHA recognizes that, although generic sodium hypochlorite (household bleach) solutions are not registered as such, they are generally recommended by the U.S. Public Health Service, Centers for Disease Control (CDC) for disinfection of environmental surfaces.

In response to your request that OSHA clarify its position, we confirm that, in accordance with the recommendations of the CDC, solutions of 5.25 percent sodium hypochlorite diluted between 1:10 and 1:100 with water are also acceptable for disinfection of environmental surfaces and for decontamination of sites following initial cleanup (i.e., wiping up) of spills of blood or other potentially infectious materials. A similar clarifying statement will be included in a subsequent change to OSHA Instruction CPL 2-2.44C.

We hope this information is responsive to your concerns. Thank you for your interest in worker safety and health.

Sincerely,



Patricia K. Clark, Director
Directorate of Compliance Programs

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close