June 26, 1992

Mr. James J. Hamulav
Kimball & Curry, P.C.
Suite 1600
2600 North Central Avenue
Phoenix, Arizona 85004

Dear Mr. Hamula:

I am responding to your letter dated February 18 which was transferred to my office from the Directorate of Compliance. My Division of Recordkeeping Requirements is responsible for administering the OSHA injury and illness recordkeeping system nationwide. Please excuse the lengthy delay in our response.

The June 4 memorandum describes OSHA's interim policy of issuing citations for violations of 29 CFR Part 1904 when employers fail to record occupational hearing loss on the OSHA Log and Summary of Occupational Injuries and Illnesses (Form 200). Employers are still expected to comply with all of the provisions of the Hearing Conservation Amendment (29 CFR Part 1910.95).

Many companies have been recording Standard Threshold Shifts (STS) of 10 dB or greater (as defined in the Hearing Conservation Amendment (HCA)) on their OSHA Logs. If these companies continue to do so, they will be in complete compliance with the injury and illness recordkeeping requirements and enforcement policy. OSHA does not want to discourage your client companies from continuing this practice. If they continue to record 10 dB shifts on their OSHA Form 200, they should revise the baselines using the HCA provisions to avoid recording the same STS more than once.

If your clients choose to record 25 dB shifts on the OSHA Form 200, the initial shift must be measured from the employee's "original baseline". The "original baseline" is the baseline audiogram first established as a result of the RCA. This could be a 1983 audiogram under the RCA, a pre-1983 audiogram grandfathered in under the RCA, or a pre-employment audiogram given to an employee hired after 1983.

When a 25 dB shift occurs and the case is recorded on the OSHA Log, that audiogram will then become the new reference baseline for future measurements. Another recordable case would not be logged until the employee suffers a 25 dB shift from the new reference baseline.

I hope you find this information useful. If you have any further questions please contact my staff at (202) 523-1463.

Sincerely,



STEPHEN A. NEWELL
Acting Director
Office of Statistics

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.