November 29, 1988

Mr. Norman Hargreaves
Reliability and Safety Manager
Koehring Cranes & Excavators, Inc.
Post Office Box 4294
Chatanooga, Tennessee 37405

Dear Mr. Hargreaves:

This is in response to your letter of October 7, concerning 29 CFR 1926.550(g)(3)(i)(G) in the Crane or Derrick Suspended Personnel Platform; Final Rule.

29 CFR 1926.550(g)(3)(i)(G) prohibits the use of machines having live booms (booms in which lowering is controlled by a brake without aid from other devices which slow the lowering speeds). The regulation is clear in its prohibition of any machines using only brakes to lower the crane boom. Your reference to 29 CFR 1926.550(g)(3)(i)(G) is not consistent with your discussion of "controlled load lowering" and automatic brakes which are addressed in 29 CFR 1926.550(g)(3)(i)(D) which stated that a system or device on the power train, other than the load hoist brake must be in place to regulate the lowering rate of speeds of the hoist mechanism (controlled load lowering). Free fall is prohibited.

The Occupational safety and health Administration (OSHA) believes that it is not necessary to promulgate a separate automatic brake requirement on its determination that the brake mechanism of an anti-two-blocking device and controlled load lowering will provide reliable protection for hoisting personnel as stated in the Crane or Derrick suspended Personnel Platforms; Final Rule, page 29123, inserted.

The standard, 29 CFR 1926.550 must be used in its entirety and should not be used in part to lessen the impact of a safety requirement.

If we can be of further service, please contact us.

Sincerely,



Thomas J. Shepich, Director
Directorate of Compliance Programs


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close