Powered by GoogleTranslate
Standard Interpretations - (Archived) Table of Contents
• Standard Number: 1910.268
• Status: Archived

Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

November 16, 1988

Mr. Michael A. D'Amico
Technical Manager
Storer Cable Communications
21 East Main Street
Clinton, Connecticut 06412

Dear Mr. D'Amico:

This is in response to your letter of September 23, 1988, to Mr. John B. Miles, concerning the use of fall protection devices during service activities by CATV personnel. Your letter was forwarded to this office for response.

The fall protection requirements of 29 CFR 1910.268, copy enclosed, are presented in that standard. When ladders are used by employees engaged in CATV work, 29 CFR 1910.268(h)(1) and (7) specify that ladders shall be properly secured in place, shall be secured (lashed) to strand, or securely lashed to the pole. In addition, 29 CFR 1910.268(g)(1) specifies that, when work is performed at positions more than 4 feet above the ground or while the worker is on a pole or a tower, safety belts and straps shall be provided and used. It is assumed that such safety belts are tied off via lanyards to fixed structure (other than a ladder) capable of providing a sufficient anchorage. Additionally, 29 CFR 1910.268(n)(7) specifies that safety belts and straps be used when adequate railings are not provided on elevated work platforms. 29 CFR 1910.268(n)(8) specifies that at all elevated work locations where adequately guarded work areas are not provided, workers shall use safety belts and straps.

Therefore, where it is necessary for an employee to work directly from a ladder at an elevation of more than 4 feet above the ground, that worker must be provided and must use a safety belt and strap. In no event is it acceptable for the worker to tie-off to a portable ladder while working aloft. A safety drop line shall be affixed to permanent structure and the worker shall tie-off to the safety drop line.

If I can be of further assistance, please contact us.

Sincerely,



Thomas J. Shepich, Director
Directorate of Compliance Programs



Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close