OSHA requirements are set by statute, standards and regulations. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This letter constitutes OSHA's interpretation of the requirements discussed. Note that our enforcement guidance may be affected by changes to OSHA rules. Also, from time to time we update our guidance in response to new information. To keep apprised of such developments, you can consult OSHA's website at http://www.osha.gov.


September 5, 1986

Mr. John M. Spann, Jr.
Vice-President, Engineering
Standard Joist Corporation
Post Office Box C
Point of Rocks, Maryland 21777

Dear Mr. Spann:

This is in response to your letter of August 14, requesting a clarification of OSHA's regulations formerly codified at 1518.751(c)(i), now 29 CFR 1926.751(c)(2).

29 CFR 1926.751(c)(2) required that, where longspan joists or trussess, 40 feet or longer, are used, a center row of bolted bridging shall be installed to provide lateral stability during construction prior to slacking of hoisting line. The word, "longspan" is a recognized product-type name for a steel joist; however, the word longspan as used in 29 CFR 1926.751(c)(2) refers to any joist or truss 40 feet or more in length.

If we may be of further assistance, please contact us.

Sincerely,


John B. Miles, Jr., Director
[Directorate of Construction]

[Correction 6/20/2005. See OSHA Directive CPL 02-01-034 "
Inspection policy and procedures for OSHA's steel erection standards for construction" published on 3/22/2002 for the current policy on OSHA's steel erection standards (1926 Subpart R) for construction.]


Archive Notice - OSHA Archive

NOTICE: This is an OSHA Archive Document, and may no longer represent OSHA Policy. It is presented here as historical content, for research and review purposes only.

Standard Interpretations - (Archived) Table of Contents

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close